Emporia
Zoning districts
11 districts, grouped by category.
Commercial
3Industrial
4General provisions
295 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.
No outdoor storage shall be located within 50 feet of a residential or planned development district. ... Outdoor storage areas shall be screened by a solid wall or fence, including solid entrance and exit gates, not less than six feet nor more than ten feet in height.
No outdoor storage shall be located within 50 feet of a residential or planned development district. Outdoor storage areas shall be screened by a solid wall or fence, including solid entrance and exit gates, not less than six feet nor more than ten feet in height.
No outdoor storage shall be located within 50 feet of a residential or planned development district.
Minimum generation of 500 kilowatts (500 KW). Maximum generation of five megawatts (five MW). ... If the medium-scale solar energy facility is ground-mounted or not flush-mounted on a principal or accessory building, the facility's height shall not exceed 15 feet at the tallest point. ... The lowest surface of any panel shall be a maximum of four feet above the finished grade
Minimum generation of 500 kilowatts (500 KW). Maximum generation of five megawatts (five MW). ... If the medium-scale solar energy facility is ground-mounted or not flush-mounted on a principal or accessory building, the facility's height shall not exceed 15 feet at the tallest point.
Minimum generation of 500 kilowatts (500 KW). Maximum generation of five megawatts (five MW). If the medium-scale solar energy facility is ground-mounted or not flush-mounted on a principal or accessory building, the facility's height shall not exceed 15 feet at the tallest point.
Minimum generation of 500 kilowatts (500 KW). Maximum generation of five megawatts (five MW).
If the medium-scale solar energy facility is ground-mounted or not flush-mounted on a principal or accessory building, the facility's height shall not exceed 15 feet at the tallest point.
The lowest surface of any panel shall be a maximum of four feet above the finished grade on which the panel is located.
Medium-scale solar energy facilities which have reached the end of their useful life, have been abandoned, or have not been in active and continuous service for a period of 12 months shall be removed at the owner's or operator's expense
Maximum generation of 500 kilowatts (500 KW). ... If the small-scale solar energy facility is ground-mounted or not flush-mounted on a principal or accessory building, the facility's height shall not exceed 15 feet at the tallest point. ... The lowest surface of any panel shall be a maximum of four feet above the finished grade
Maximum generation of 500 kilowatts (500 KW). ... If the small-scale solar energy facility is ground-mounted or not flush-mounted on a principal or accessory building, the facility's height shall not exceed 15 feet at the tallest point.
Maximum generation of 500 kilowatts (500 KW). If the small-scale solar energy facility is ground-mounted or not flush-mounted on a principal or accessory building, the facility's height shall not exceed 15 feet at the tallest point.
Maximum generation of 500 kilowatts (500 KW).
If the small-scale solar energy facility is ground-mounted or not flush-mounted on a principal or accessory building, the facility's height shall not exceed 15 feet at the tallest point.
The lowest surface of any panel shall be a maximum of four feet above the finished grade on which the panel is located.
Small-scale solar energy facilities which have reached the end of their useful life, have been abandoned, or have not been in active and continuous service for a period of 12 months shall be removed at the owner's or operator's expense
The purpose of this division is to permit the use of exterior lighting at the minimum level necessary for nighttime safety, utility, security, productivity, enjoyment, and commerce;
The purpose of this division is to establish standards for landscape architecture, site design, site buffering, and landscape screening.
To provide shade, screen views, and mitigate stormwater runoff, all vehicle parking areas shall include landscaping as required in this section.
Source documents