Pasadena
Zoning districts
45 districts, grouped by category.
Overlay
4Alcohol Density Overlay District - AD-1
Alcohol Density Overlay District - AD-2
HD-1 (Upper Hastings Ranch Area) Overlay District
- Max height
- 25 ft
- Front setback
- 40 ft
- Permitted uses
- 3
Height Limit Overlay District 1
- Max height
- 32 ft
Commercial
10- Max height
- 36 ft
- Front setback
- 15 ft
General Commercial-1
- Min lot
- 15,000 sq ft (0.34 ac)
Colorado/Lake
- Max height
- 161 ft
- Front setback
- 14.5 ft
- Permitted uses
- 2
Foothill Boulevard, Craig Avenue and White Street
- Max height
- 45 ft
- Permitted uses
- 4
Walnut - Los Robles
- Max height
- 145 ft
- Permitted uses
- 4
PD-18 - Colorado/El Nido
- Max height
- 36 ft
- Permitted uses
- 5
South Lake Avenue Development
- Max height
- 50 ft
- Front setback
- 0 ft
- Permitted uses
- 1
Kinneloa Annexation
- Max height
- 22 ft
Allesandro Place/Fair Oaks
- Max height
- 50 ft
- Front setback
- 20 ft
Seco Street
- Max height
- 30 ft
- Front setback
- 15 ft
Other
10Marengo-Bellevue
- Front setback
- 20 ft
PD-15 - Huntington Hotel
- Max height
- 112 ft
- Permitted uses
- 3
Colorado - Los Robles
- Max height
- 78 ft
- Front setback
- 0 ft
- Permitted uses
- 1
Montana I and II
- Max height
- 80 ft
- Front setback
- 0 ft
- Permitted uses
- 1
Rose Avenue
- Min lot
- 5,000 sq ft
- Max height
- 30 ft
- Front setback
- 15 ft
- Max density
- 7.3 du/ac
- Permitted uses
- 2
100 West Walnut Planned Development
Colorado Hill Planned Development
- Max height
- 78.5 ft
- Front setback
- 0 ft
- Permitted uses
- 5
The Affinity
- Front setback
- 0 ft
- Max density
- 87 du/ac
- Permitted uses
- 15
- Front setback
- 20 ft
Residential
19PD-17 - Rose Townhomes
- Min lot
- 5,000 sq ft
- Max height
- 24 ft
- Front setback
- 20 ft
- Max density
- 12.9 du/ac
- Permitted uses
- 2
PD-21 - Montgomery Engineering
- Max height
- 60 ft
- Permitted uses
- 2
Lincoln Triangle Townhouse
- Front setback
- 20 ft
- Permitted uses
- 4
Salvation Army
- Max height
- 45 ft
- Front setback
- 15 ft
- Permitted uses
- 1
Vista Del Arroyo Bungalows
- Max height
- 35 ft
- Front setback
- 10 ft
- Max density
- 10 du/ac
- Permitted uses
- 9
King's Village
- Min lot
- 7,200 sq ft
- Permitted uses
- 4
Community Arms
Artisan Village
- Max height
- 36 ft
- Front setback
- 20 ft
- Permitted uses
- 4
Desiderio Homes
- Max height
- 23 ft
- Permitted uses
- 1
Mountain Street Classics Townhomes
- Max height
- 36 ft
- Front setback
- 20 ft
- Permitted uses
- 9
Eaton Wash Residential
- Min lot
- 4,500 sq ft
- Front setback
- 22 ft
- Max density
- 4.9 du/ac
El Mirador
- Min lot
- 15,000 sq ft (0.34 ac)
- Max height
- 20 ft
- Max density
- 5 du/ac
- Permitted uses
- 9
- Max height
- 32 ft
- Front setback
- 20 ft
- Permitted uses
- 9
Multi-Family Residential (RM-32)
- Max height
- 3 ft
- Front setback
- 20 ft
- Permitted uses
- 10
Multi-Family Residential (RM-48)
- Max height
- 38 ft
- Front setback
- 20 ft
- Permitted uses
- 10
- Max density
- 17.43 du/ac
- Max height
- 100 ft
- Min lot
- 910 sq ft
- Max height
- 72 ft
- Max density
- 17.43 du/ac
- Permitted uses
- 1
General provisions
769 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.
Mature healthy street trees shall not be removed unless the removal is ordered by the Director of Public Works in compliance with Chapter 8.52 (City Trees and Tree Protection Ordinance) of the Municipal Code.
The tree species shall be the same as the most prevalent tree type on the block unless the City's Street Tree Plan specifies a different species.
Every use, including a change or expansion of a use or structure, shall have appropriately maintained off-street parking and loading spaces or areas in compliance with the regulations identified in this Chapter.
Small additions with a maximum aggregate total of 500 square feet, including the construction of an accessory structure (e.g., a pool house or workshop) may be made to existing residences without requiring the two-car covered parking requirement
Each uncovered parking space shall provide a minimum dimension of 8.5 feet wide by 18 feet deep.
Parking at grade shall be located in the rear 40 percent of the site.
The parking area shall not be visible from the main garden, and it shall be screened from the street or at grade from an adjacent lot by building walls, or freestanding walls, or landscaped elements at least six feet in height.
On double frontage lots, no parking shall be located in the front 30 percent of the site along each street frontage.
A detached single-family dwelling unit located in the front 60 percent of the site may incorporate parking; provided, the: Parking is provided within the building envelope and not in a separate structure. Parking is limited to two spaces and is for the exclusive use of the residents of the dwelling and not for residents of other portions of the project.
A Minor Conditional Use Permit, in compliance with Section 17.61.050, may be approved to allow the reduction in the number of spaces to not less than 0.50 space per dwelling unit
All off-street parking in residential zoning districts required to serve a residential use shall be located on the same site as the use served but shall not be located within a required front or corner side setback
At least one space for each unit shall be located on-site so that tenants can park near their unit.
Access to parking spaces, other than four or fewer spaces serving a residential use, shall not require backing across a property line abutting a street.
A Minor Conditional Use Permit, granted in compliance with Section 17.61.050, shall be required to allow valet parking.
Parking facilities for commercial uses shall contain shopping cart storage areas for appropriate uses (e.g., supermarkets, drugstores, etc.).
Parking spaces shall be double-striped.
An additional width of one foot shall be provided for each parking space the length of which is contiguous to a fence, structure, wall, or other obstruction.
All spaces shall have wheel stops three feet from a fence, wall, or required landscaped area.
The width of each driveway shall comply with the minimum requirements of this Section and also provide a minimum of one foot of additional clearance on each side of the driveway to a vertical obstruction exceeding one-half foot in height.
Driveway approaches shall be at least 12 feet wide at the curb and shall taper to driveway width at the front property line.
Source documents
The chapters of the adopted code that were retrieved, read and extracted from. Everything above traces back to one of these.