Pasadena, California · District

PD-26

Colorado - Los Robles
OtherMixed UseAll Pasadena districts0

Dimensional standards

PD-26 lot requirementsSTREETbuildable areaFront 0 ftMAX HEIGHT78 ftMAX LOT COVERAGE50%MAX FAR3.1
Plan view of the district’s stated lot requirements. Solid line: the property line. Dashed: the setback lines the ordinance imposes; a building must stay inside the tinted envelope. Drawn from the figures extracted below — illustrative, not a survey.

Uses

Extracted standards

12 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Fencing & walls

Other

  • Active ground floor uses35 pct

    A minimum of 35 percent of the gross floor area of the ground floor of the building shall be devoted to active, non-financial, pedestrian-oriented uses

  • Building appurtenances shall not exceed 20 feet above the building height limit set forth in the PD

  • Maximum appurtenance roof coverage30 pct

    shall cover no more than 30 percent of the total roof area of the building.

  • Minimum loading dock clearance14 ft

    The loading dock shall have a minimum vertical clearance of 14 feet

  • Minimum loading dock length45 ft

    and a minimum length of 45 feet to the Union Street property line.

  • Minimum loading dock width26 ft

    Loading dock size shall be a minimum width of 26 feet

Parking

  • Maximum parking slope5 pct

    The slope of all parking areas, excluding ramps shall not exceed five percent grade.

  • Maximum ramp grade16 pct

    have a maximum ramp grade not to exceed 16 percent

  • Maximum tandem parking85 pct

    No more than 85 percent of total parking for the project shall be provided in a tandem parking configuration.

  • Minimum ramp length75 ft

    The ramp leading to the subterranean parking shall be a minimum of 75 feet in length

Signage

From the ordinance

New construction shall not exceed 270,000 square feet of gross floor area (excluding outdoor dining areas) and shall substantially conform to the site plan entitled Exhibit 1.
PD-26

Parking requirements

{
  "compact": "277 spaces",
  "employee": "375 spaces",
  "ADA Handicapped": "16 spaces",
  "customer/visitor": "104 spaces"
}