Dimensional standards

RM-16 lot requirementsSTREETbuildable areaFront 20 ftRear 5 ftSide 15 ftMAX HEIGHT32 ft
Plan view of the district’s stated lot requirements. Solid line: the property line. Dashed: the setback lines the ordinance imposes; a building must stay inside the tinted envelope. Drawn from the figures extracted below — illustrative, not a survey.

Uses

Extracted standards

13 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • On sites with 60 feet or more of street frontage, at least 50 percent of the site width shall be occupied by building volume at the front setback.

  • On sites with less than 60 feet of street frontage, at least 40 percent of the site width shall be occupied by building volume at the front setback.

  • Maximum facade length along street60 ft

    No facade along the street may be longer than 60 feet.

  • Light and air separation for major windows15 ft

    When new construction faces major windows or doors in existing structures on an adjacent lot, or a new wall is proposed to contain major windows or doors, the minimum building separation shall be 15 feet, for a minimum of three feet beyond each side of the width of the window or door at all stories.

  • Light and air separation for minor windows10 ft

    When new construction faces minor windows in existing structures on an adjacent lot, or a new wall is proposed to contain minor windows, the minimum separation shall be 10 feet for a minimum three feet beyond each side of the width of the window at all stories.

  • Main garden enclosure percentage50 pct

    On sites with 60 feet or more of street frontage, buildings shall enclose the garden for at least 50 percent of its perimeter.

  • Main garden enclosure percentage (small sites)40 pct

    On sites with less than 60 feet of street frontage, buildings shall enclose the garden for at least 40 percent of its perimeter.

  • Main garden minimum dimension20 ft

    The main garden shall be a rectangular shape and shall have a minimum dimension of 20 feet in either direction.

  • Main garden perimeter bounded by building/landscape75 pct

    On all sites, at least 75 percent of the main garden's perimeter shall be bounded by building walls, architectural elements such as low walls or trellises, or linear landscape elements such as hedges or rows of trees.

  • Main garden planting percentage50 pct

    At least 50 percent of the main garden shall be planted.

  • Side separation from adjacent lots15 ft

    Proposed structures shall be set back from buildings on adjacent lots along the side property line by a minimum of 15 feet, from the sidewalk across the property frontage to a minimum of 40 feet behind the front setback line.

  • Minimum site width occupied by building/landscape70 pct

    At least 70 percent of the width of a site must be occupied by building volume, other architectural elements such as low walls and trellises, or linear landscape elements such as hedges or rows of trees.

Setback

From the ordinance

The following minimum standards for building setbacks apply... minimum front setback shall be 20 feet. In the RM-16 district... maximum height of structures is 23 feet to the top plate and 32 feet to the highest ridge line.
17.22.070