Pasadena, California · District

PD-31

Montana I and II
OtherMixed UseAll Pasadena districts0

Dimensional standards

PD-31 lot requirementsSTREETbuildable areaFront 0 ftMAX HEIGHT80 ft / 6 storiesMAX LOT COVERAGE72.8%MAX FAR3.1
Plan view of the district’s stated lot requirements. Solid line: the property line. Dashed: the setback lines the ordinance imposes; a building must stay inside the tinted envelope. Drawn from the figures extracted below — illustrative, not a survey.

Uses

Extracted standards

26 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Design

  • Design guidelines required

    All development, including the design of the Montana I and II, shall be subject to citywide design principles and to the design guidelines for the Central District, adopted by the City Council on October 21, 2002.

Height

Lighting

  • Lighting plan required

    A lighting plan shall be prepared for the project to provide for the safe movement of people and vehicles throughout the project site.

Other

  • C&D waste management plan required

    The applicant shall comply with the provisions of the Pasadena Municipal Code Chapter 8.62.

  • Courtyard width24 ft

    A landscaped courtyard with a width of 24 feet or greater shall separate the new structure from the existing parking structure and shall be visible from Euclid Avenue and the pedestrian walkway.

  • Driveway visibility distance50 ft

    Pedestrian and vehicle street visibility for a distance of 50 feet from each exit shall be maintained.

  • Loading space dimensions

    One off-street space with dimensions of 10 feet X 20 feet X 10 feet shall be provided.

  • Maximum drive entrances2 count

    Ingress and egress shall be limited to two drive entrances on Euclid Avenue.

  • Maximum drive entrances2 count

    Ingress and egress shall be limited to two drive entrances on Euclid Avenue.

  • Lot coverage shall not exceed 64 percent.

  • Development will have approximately 96,300 square feet and shall include at least 2,500 square feet of commercial use on the ground floor.

  • The Development shall include at least 7,000 square feet of retail use fronting on Colorado Boulevard, with a minimum depth of 30 feet from the property line.

  • Minimum retail depth30 ft

    The Development shall include at least 7,000 square feet of retail use fronting on Colorado Boulevard, with a minimum depth of 30 feet from the property line.

  • Neither a parking structure nor access to parking is permitted on Colorado Boulevard. Ingress and egress shall be limited to two drive entrances on Euclid Avenue.

  • Pedestrian walkway width28 ft

    A landscaped pedestrian walkway of at least 28 feet in width shall extend from Colorado Boulevard between the existing office building and the new structure, connecting to the corner plaza at Garfield Avenue and Union Street.

Parking

  • Maximum ground floor parking50 pct

    Parking and parking related uses shall not exceed 50 percent of ground floor area.

  • Maximum ground floor parking50 pct

    Parking and parking related uses shall not exceed 50 percent of ground floor area.

  • Maximum parking ramp grade16 pct

    The maximum grade of ramps that serve parking exclusively dedicated to the residential units shall be 16 percent.

  • Ramp grade near entrance2 pct

    Ramps shall not exceed 2 percent for a distance of 10 feet from an entrance at the property line.

  • Tandem parking space dimensions

    One tandem space (9 feet by 34 feet) may be substituted for one parking space required for a residential unit.

Setback

From the ordinance

The FAR for the entire Planned Development site shall not exceed 3.1. The number of residential units shall not exceed 50. Lot coverage shall not exceed 72.8 percent of the parcels on the Montana I block.
PD-31

Parking requirements

{
  "other": "per Zoning Code",
  "residential": "1.5 spaces per unit"
}