Section 3-6-8(C)(1)1 standards

Site Plans shall be approved or disapproved within 60 days after it has been officially submitted for approval or, if state agency review is required, within 35 days of receipt of approvals from all reviewing agencies.

Section 4-1-3(D)(2), Section 4-7-13 standards

The intent of this district is to permit certain larger scale manufacturing with outside storage, warehousing, and/or product display.

Section 4-1-3(E)(1), Section 4-8-36 standards

Resort Communities shall be served by centralized water and sewer utilities, whether public or privately operated

Section 4-2-31 standards

Flagpoles less than 50 ft. in height; Flagpoles 50 ft. or greater in height shall require a Special Exception Permit

Section 4-2-42 standards

Land restricted for building by utility easements shall be considered unusable and shall account for no more than 10% of the minimum required area on any lot.

Section 4-2-53 standards

Steep slopes are those areas in the County with slopes greater than 15%. No driveway shall be constructed with a grade greater than 10%.

Section 4-3-15 standards

Covered porches (on any façade) may project not more than 5 ft. into any required setback. Uncovered porches and decks may project not more than 8 ft. into a required rear setback.

Section 4-6-13 standards

Side and rear setbacks: None, except in cases where uses abut an existing Residential, Agricultural, or Planned Development district; then, the same as required for the abutting district. Accessory structures not permitted in front yard. Buildings may be erected to a height of 50 ft.; provided that required front, side, and rear setback minimum standards shall be increased 1 foot for each foot in height over 35 ft.

Section 4-7-12 standards

Buildings may be erected to a height of 50 ft.; provided that required front, side, and rear setback minimum standards shall be increased 1 foot for each foot in height over 35 ft. Buildings may be erected to a height greater than 50 ft. upon the issuance of a Special Exception.

Section 4-8-36 standards

Resort Communities shall be served by centralized water and sewer utilities. All new utility lines shall be placed underground. Setbacks at the edge of the RC District shall conform to the setback requirements of the adjoining district, or to the setback requirements of the RC District, whichever is greater. Accessory structures are not permitted in front yards. In dwellings, the maximum windowsill height on the second floor shall be 21 feet above average grade. Non-residential structures may be erected to a height of 50 ft.; provided that required front, side, and rear setback minimum standards shall be increased 1 foot for each foot in height over 45 ft.

Section 4-8-413 standards

The regulations of this Article are intended to permit Mixed-Use Development Districts in the Courthouse West primary settlement area and the Route 3/Route 301 primary settlement area

Section 4-8-49 standards

Mixed-Use developments shall be served by centralized water and sewer utilities. All new utility lines shall be placed underground. Setbacks at the edge of the M-U District shall conform to the setback requirements of the adjoining district, or to the setback requirements of the M-U District, whichever is greater. Accessory structures are not permitted in front yards. In dwellings, the maximum windowsill height on the second floor shall be 21 feet above average grade. Non-residential buildings may be erected to a height of 50 ft.; provided that required front, side, and rear setback minimum standards shall be increased 1 foot for each foot in height over 45 ft.

Section 4-9-2 and 4-9-37 standards

Cluster development as allowed by the provisions of this article shall be permitted only in the following districts: A-2, A-3, R-1, R-2, R-3. All cluster developments shall provide open space in accordance with Table IV-9.

Section 5-1-2(C)

The purpose of the HCOD is to: (i) Maintain the long-term safety and mobility function of Route 3 and Route 301;

Section 5-1-2(C)4 standards

The purpose of the HCOD is to: (i) Maintain the long-term safety and mobility function of Route 3 and Route 301;

Section 5-1-2(D)

The purpose of Military Compatibility Area Overlay District (MCAOD) is to: (i) Recognize the existence of Naval Support Facility Dahlgren (NSF) and address the interaction between NSF Dahlgren and surrounding land uses;

Section 5-2-110 standards

All area within the County (CPBA) is either designated as a Resource Protection Area (RPA) or as a Resource Management Area (RMA).

Section 5-2-1(A)18 standards

The Chesapeake Bay Preservation Area Overlay (CBPA) shall apply to all lands identified as Chesapeake Bay Preservation Areas (CBPAs) as designated by the Board of Supervisors and as shown on the Chesapeake Bay Map.

Section 5-2-7 and 5-2-85 standards

A 100-foot buffer area located adjacent to and landward of the components... Any development or redevelopment equal to or greater than 2,500 square feet of land disturbance in the CBPA shall be accomplished through a Plan of Development process.

Section 5-3-166 standards

New construction or substantial improvement of any residential structure in Zones AE, AH, and A, shall have the lowest floor, including basement, elevated to or above the base flood level plus 12 inches.