Winchester
Zoning districts
11 districts, grouped by category.
Commercial
3Central Business District
- Max height
- 75 ft
- Front setback
- 0 ft
- Max density
- 48.4 du/ac
- Permitted uses
- 49
Highway Commercial District
- Min lot
- 10,000 sq ft
- Max height
- 35 ft
- Front setback
- 35 ft
- Permitted uses
- 49
Commercial Industrial District
- Min lot
- 20,000 sq ft (0.46 ac)
- Front setback
- 35 ft
- Permitted uses
- 56
Other
2Residential
3Industrial
2General provisions
193 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.
Every part of every required yard shall be open and unobstructed from the ground to the sky except as hereinafter provided or as otherwise permitted in this Ordinance.
Fences/walls. Prior to the installation of any fence, retaining wall or non-retaining wall, a permit shall be obtained from the Administrator. Fences shall be subject to the following requirements pertaining to height, opacity, minimum setback, and special provisions.
Fences shall be subject to the following requirements pertaining to height, opacity, minimum setback, and special provisions. Fences in a non-primary front yard or corner side yard, may have a zero-foot setback from the corresponding property line, provided that the fence is no greater than four-feet in height and has a minimum of 25 percent openness.
The maximum density that a Planned Unit Development may be approved for is 16-dwelling units per gross acre, except as provided for in Sections 13-1-5.2.a through 13-1-5.12 below.
The maximum height of any building or structure in a PC District shall be 35 feet.
Cottage housing development design standards... maximum ground floor gross area... 864 square feet... minimum separation of 12 feet... 400 square feet per cottage unit of common open space... 200 square feet of usable private open space... 1,000 feet or one block...
A zoning overlay district, the Historic Winchester District—(HW) is hereby established. The boundaries of this district are delineated upon the City of Winchester, Virginia Zoning Map.
This district establishes regulations intended to encourage the innovative, adaptive reuse of the former Stewart Street hospital site with lower intensity uses and development impact on adjacent zoning districts than existed prior to the relocation of the general hospital.
Minimum lot area for higher education 10,000 sq ft; lot width 100 ft; setbacks 35 ft front, 10 ft side, 25 ft rear; height 35 ft (45 ft for public/semipublic with increased side yards).
The purpose of this section is to regulate uses, structures, and lots that do not conform to their current and respective zoning districts.
The purpose of these requirements is to promote the orderly development of certain activities in the City and to ensure that such activities are developed in a manner harmonious with surrounding properties and in the interest of the general public welfare.
Multifamily residential site plans shall devote 20 percent of the required landscaping, buffering, and recreation area to active and passive recreational facilities (such as playground equipment, swimming pools, ball courts, community buildings with open common areas, etc.), not to exceed 35 percent of the gross landscaped area requirement for projects outside of the Historic District (HW) and not to exceed 50 percent of the gross landscaped area requirement for projects in the Historic District (HW).
Single family detached dwellings. Public parks... Rear setbacks for all uses in this district — 25 feet. Buildings may be erected up to 35 feet from grade...
Medium Density Residential District—MR. Single family detached dwellings permitted. Front setback 30 ft, rear setback 25 ft. Only one main building per lot.
Single family detached dwellings or two family dwelling units - 3,000 square feet per unit. Multifamily dwellings - density shall not exceed one dwelling unit for each 3,300 square feet of the Total Project Area...
Multifamily dwellings - density shall not exceed one dwelling unit for each 3,300 square feet of the Total Project Area... Townhouse dwellings - density shall not exceed one dwelling unit for each 3,300 square feet of the Total Project Area.
Other permitted and conditional uses - 10,000 square feet. All other permitted and conditional uses - 70 feet. All other uses: 30 feet or more. Other permitted and conditional uses - 25 feet. For multifamily dwellings and all other uses: 25 feet or more.
Two family dwelling units - 25 feet per unit.
No lot or townhouse unit shall be less than 20 feet in width... For single family detached dwellings, two unit townhouses and two-family dwellings: 25 feet or more. Townhouse dwellings - 10 feet or more... For two family and townhouse dwellings: 20 feet or more.
Townhouses with more than two units attached or multifamily dwellings: 35 feet or more. Multifamily Structures - 25 feet... For multifamily dwellings and all other uses: 25 feet or more.
Source documents
The chapters of the adopted code that were retrieved, read and extracted from. Everything above traces back to one of these.
- Chapter 1131.5K charsRead →
- Chapter 1056K charsRead →
- Chapter 1129.2K charsRead →
- Chapter 1223.6K charsRead →
- Chapter 1322.9K charsRead →
- Chapter 1481K charsRead →
- Chapter 1546.7K charsRead →
- Chapter 1667.2K charsRead →
- Chapter 17131.1K charsRead →
- Chapter 1889K charsRead →
- Chapter 1924.8K charsRead →
- Chapter 26.9K charsRead →
- Chapter 2037.4K charsRead →
- Chapter 218.7K charsRead →
- Chapter 2214.4K charsRead →
- Chapter 2336K charsRead →
- Chapter 24467.1K charsRead →
- Chapter 2577K charsRead →
- Chapter 2634.6K charsRead →
- Chapter 2722.7K charsRead →
- Chapter 2817.5K charsRead →
- Chapter 2940.1K charsRead →
- Chapter 316.2K charsRead →
- Chapter 417.6K charsRead →
- Chapter 535.2K charsRead →
- Chapter 620K charsRead →
- Chapter 716.4K charsRead →
- Chapter 827.5K charsRead →
- Chapter 946.4K charsRead →