Abingdon
Zoning districts
22 districts, grouped by category.
Other
4Industrial
3Historic
5Residential
8Low-Density Residential
- Max height
- 35 ft
- Permitted uses
- 12
Medium-Density Residential
- Max height
- 35 ft
- Permitted uses
- 5
High-Density Residential
- Max height
- 35 ft
- Permitted uses
- 5
Mixed Residential
- Max height
- 35 ft
- Max density
- 2 du/ac
- Permitted uses
- 8
Mixed High-Density Residential
- Max height
- 35 ft
- Permitted uses
- 12
General provisions
318 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.
The Administrator's response shall be provided within 90 days of the date of the request, unless the requestor agrees to a longer period of time.
All structures shall be no taller than 35 feet... Structures shall be located 15 feet or more from the property line of an existing alley.
All structures shall be no taller than 35 feet, except: a. The height limit for dwellings may be increased up to 45 feet and up to three stories...
Except accessory buildings, which shall: 1. Be no closer than five feet to any side or rear property line; 2. Be no taller in height than the main structure on the property;
The OH District shall follow the general established pattern already in existence in the district insofar as area, setback, frontage, yard, and height regulations are concerned. Except accessory buildings, which shall: 1. Be no closer than five feet to any side or rear property line; 2. Be no taller in height than the main structure on the property; and 3. Follow the use performance standards provided in Article VII.
The boundaries of the EC District shall be the boundaries of the Office and Institutional District, business districts, and Limited Industrial Districts... Uses which are permitted in the underlying districts shall be permitted in the EC District. No temporary, mobile or modular structure, including portable storage containers, may be placed or used in this Zoning District...
Unless otherwise specified herein, uses which are permitted in the underlying districts shall be permitted in the EC District. ... No temporary, mobile or modular structure, including portable storage containers, may be placed or used in this Zoning District, with the exception that temporary structures may be placed upon property within this District by contractors for their use during development and construction upon property within this District.
Each PTD shall be subject to the following site development regulations: ... Minimum frontage and lot width: None ... The maximum height may be increased provided each required yard (side, rear, or buffer) adjoining a residential district or use is increased by two feet above the minimum for each foot in height over 45 feet.
Minimum frontage and lot width: None. The maximum height may be increased provided each required yard (side, rear, or buffer) adjoining a residential district or use is increased by two feet above the minimum for each foot in height over 45 feet. In no case shall a buffer screening area adjoining any residential district or use be less than 10 feet in width. Public water and sewer services are required in the PTD.
Primary residential uses are allowed... No PUD shall be allowed which does not incorporate a variety of dwelling types. The maximum gross density shall not exceed 20 units per acre... A planned unit development shall contain a minimum of five acres of land. The conserved open space within a planned unit development shall be at least 20% of the gross acreage... Structures within the planned unit development shall be connected to public water and sewer lines and all utility lines shall be placed underground.
The maximum gross density shall not exceed 20 units per acre... A planned unit development shall contain a minimum of five acres of land... The conserved open space within a planned unit development shall be at least 20% of the gross acreage of the planned unit development.
For purposes of this article, the following terms shall have the meanings respectively ascribed to them... HEIGHT: For the purpose of determining the height limits in all zones of this article and shown on the zoning map, the datum shall be mean sea level (MSL) elevation unless otherwise specified.
Permitted uses: open space uses... Prohibited uses: new residential development within floodway areas...
All uses, activities and development occurring within the Flood Hazard Overlay shall be undertaken only upon the issuance of a special use permit.
"B" in a Use Matrix cell indicates that the use type in that row is allowed by-right... "SUP" ... only upon approval of a special use permit... Blank cells ... prohibited.
Accessory buildings shall meet the standards of the underlying zoning district... shall not exceed 40% of the gross floor area of the main structure.
Accessory buildings shall meet the standards of the underlying zoning district, including yards and height regulations unless otherwise specified in this chapter.
The minimum required area for the use shall be three acres.
The minimum required area for the use shall be three acres.
An oil/sand interceptor, or comparable wastewater system, with a minimum capacity of 120 cubic feet shall be provided within the building for the protection of the sewers.
Source documents
The chapters of the adopted code that were retrieved, read and extracted from. Everything above traces back to one of these.
- Chapter 122.2K charsRead →
- Chapter 10161.3K charsRead →
- Chapter 11217.4K charsRead →
- Chapter 121.2K charsRead →
- Chapter 245.3K charsRead →
- Chapter 3158.8K charsRead →
- Chapter 440.3K charsRead →
- Chapter 5193.6K charsRead →
- Chapter 623.3K charsRead →
- Chapter 7213.7K charsRead →
- Chapter 8328K charsRead →
- Chapter 923.5K charsRead →