Dimensional standards
Servicing
- Geographic extent
- East Colorado Specific Plan area
Extracted standards
9 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Parking
- Maximum driveways for frontageFrontageThe length of a lot line that touches a public street. under 200 feet1 count
For Projects with less than 200 feet of primary street frontage, a maximum of 1 two-lane driveway shall be permitted.
- Maximum driveways for frontageFrontageThe length of a lot line that touches a public street. over 200 feet2 count
For sites with more than 200 feet of primary street frontage, a maximum of 2 two-lane driveways shall be permitted.
- Minimum parkingMinimum parkingThe number of off-street spaces a development must provide before it may open. buffer hedge heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.3 ft
Landscaping used as a parking buffer shall be located in the required parking setback and shall include hedges or shrubs a minimum of 3 feet in height at the time of planting
- Minimum building floor area depth along primary frontageFrontageThe length of a lot line that touches a public street.35 ft
Along primary frontages, all floors of parking structures shall be lined with building floor area (e.g. commercial or residential uses) or Publicly Accessible Open Space for a minimum of 35 feet in depth.
- Minimum structured parking setbackSetbackThe distance a building must be held back from a lot line. from secondary frontageFrontageThe length of a lot line that touches a public street.5 ft
Along secondary frontages, parking structures shall be set back a minimum of 5 feet.
- Minimum surface parking setbackSetbackThe distance a building must be held back from a lot line. from primary frontageFrontageThe length of a lot line that touches a public street.30 ft
Parking lots shall be set back a minimum of 30 feet from the primary frontage
- Minimum surface parking setbackSetbackThe distance a building must be held back from a lot line. from RM zoning5 ft
and a minimum of 5 feet from RM zoning.
- Minimum surface parking setbackSetbackThe distance a building must be held back from a lot line. from secondary frontageFrontageThe length of a lot line that touches a public street.10 ft
a minimum of 10 feet from any secondary frontage
- Minimum subterranean parking setbackSetbackThe distance a building must be held back from a lot line. from Green Street and RM zoning5 ft
Subterranean parking shall be set back a minimum of 5 feet from Green Street and RM zoning.
From the ordinance
The number of spaces for Research and Development land uses shall be 2 per 1,000 sq ft regardless of zoning district.
Parking requirements
{
"Research and Development": "2 per 1,000 sq ft"
}