17.38.020.A, 17.38.060, 17.38.070.G.1.a.1
Dimensional standards
Housing
Servicing
- Geographic extent
- Lamanda Park Specific Plan
Uses
Extracted standards
13 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Lighting
- Ground floor façade lighting frequency30 ft
Lighting shall be located on façades facing streets and public open spaces at a frequency of every 30 feet or less.
Other
- Arcade minimum depth8 ft
Arcades shall be a minimum of 8 feet from back of column to building façade.
- Awning minimum projection3 ft
Any ground floor shading shall project a minimum of 3 feet from the façade and allow a minimum of 8 feet of vertical clearance from sidewalk elevation.
- Colorado Boulevard stepback
Along Colorado Boulevard, buildings shall not exceed 20 feet in height before stepping back 10 feet in depth.
- Façade length exemption for CF
Projects in CF are exempt from the façade length requirement.
- Gallery maximum frontageFrontageThe length of a lot line that touches a public street.50 pct
Galleries shall be limited to one-story in height and 50 percent of the building frontage.
- Maximum balcony projection4 ft
Balconies may project a maximum of 4 feet from the building façade but shall not extend beyond the sidewalk line or within 6 feet of any interior property line.
- Maximum roof deck coverage60 pct
The sum of all roof decks on a single building shall not exceed a maximum coverage of 60 percent of the roof area.
- Maximum wall/fence heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.72 in
In CF, walls and fences shall have a maximum height of 72 inches above the sidewalk elevation. Walls and fences over 48 inches in height shall be set back a minimum of 5 feet from the sidewalk line, separated by planted area.
- Minimum parkway frontageFrontageThe length of a lot line that touches a public street. for non-residential30 pct
For mixed-use and non-residential projects, parkway length shall be no less than 30 percent of street frontage.
In CF, all required setback areas shall be landscaped except walkways, driveways, and utilities required by Building Code.
- Varied roof lines allowance
A maximum of 30 percent of a building's footprint may exceed the height limit set in Figure LPSP-8 by up to 12 feet.
Setback
- Interior setbackSetbackThe distance a building must be held back from a lot line. adjacent to RM/RS15 ft
Projects shall have a minimum setback of 15 feet where adjacent to a RM/RS district.
From the ordinance
Allow flexibility for light industrial, custom manufacturing, creative office and research & development uses... In CF, walls and fences shall have a maximum height of 72 inches above the sidewalk elevation.