Extracted standards
6 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Side encroachment plane angle for City of Gardens30 deg
Principal and accessory structures using the City of Gardens Standards that adjoin an RS district along a side lot line shall provide a five-foot side yard setback and shall not be located within a side encroachment plane sloping upward and inward to the site at a 30-degree angle measured from the vertical, commencing six feet above the existing grade along the side lot line.
- SetbackSetbackThe distance a building must be held back from a lot line. for commercial/industrial abutting residential15 ft
In the commercial and industrial zoning districts, a 15-foot side and/or rear setback shall be provided adjacent to any abutting residential zoning district.
- Maximum pavement in front/corner setbackSetbackThe distance a building must be held back from a lot line. in residential zones30 pct
Not more than 30 percent of the front or corner side setback area shall be paved.
- Encroachment plane angle for nonresidential abutting RM-16/32/4845 deg
Principal and accessory structures shall not be located within an encroachment plane sloping upward and inward to the site at a 45-degree angle, commencing 20 feet above the existing grade at the property line of the abutting residential zoning district.
- Encroachment plane angle for nonresidential abutting RS/RM-1245 deg
Principal and accessory structures shall be located within an encroachment plane sloping upward and inward to the site at a 45-degree angle, commencing six feet above the existing grade at the property line of the abutting residential zoning district.
- Side encroachment plane angle for RS/RM-1230 deg
Principal structures within the RS and RM-12 zoning districts shall not be located within a side setback encroachment plane sloping upward and inward to the site at a 30-degree angle measured from the vertical, commencing six feet above the existing grade along the interior side property line.
From the ordinance
In the commercial and industrial zoning districts, a 15-foot side and/or rear setback shall be provided adjacent to any abutting residential zoning district. Principal structures within the RS and RM-12 zoning districts shall not be located within a side setback encroachment plane sloping upward and inward to the site at a 30-degree angle measured from the vertical, commencing six feet above the existing grade along the interior side property line.