Dimensional standards
Uses
Extracted standards
9 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Design
- Exterior materials match
When visible from a public right-of-way, the exterior finish, trim, and roof materials shall be demonstrably similar to the finish, trim, and roof materials found on the primary structure or to materials found within properties along the blockface.
- Roof pitch match
Proposed accessory structures shall maintain a roof pitch equal to or within 1/12 of the predominant roof pitch of the existing primary dwelling.
Height
- Encroachment plane for accessoryAccessory useA secondary activity customarily incidental to the main use of the lot — a garage, a home office. structures
The overall height of an accessory structure may rise above the nine-foot height limit as it steps or slopes away from the two-foot initial setback, but shall not intercept an encroachment plane sloping inward from a point nine feet in height (beginning at the two-foot setback) and rising a maximum of one and one-half feet for each one foot of distance starting at the two-foot setback.
Other
- Maximum aggregate floor area of accessoryAccessory useA secondary activity customarily incidental to the main use of the lot — a garage, a home office. structures600 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
The maximum size of all accessory structures on a site shall not exceed an aggregate of 600 square feet or six percent of the lot size, whichever is greater.
- Pool/hot tub distance from property line5 ft
Pools, hot tubs, and related equipment, and all mechanical equipment shall not be closer than five feet from a property line.
- Separation from other structures6 ft
An accessory structure, other than mechanical equipment, a hot tub, or a swimming pool, shall maintain a minimum separation of six feet from any other structure (excluding walls and fences) on the site.
- Separation from utility pole4 ft
When a utility pole is located on the same site as a proposed accessory structure, a minimum separation of at least four feet shall be maintained between the pole and the accessory structure.
Setback
- Prohibition in required front or corner side setbackSetbackThe distance a building must be held back from a lot line.
An accessory structure shall not occupy a required front or corner side setback.
An accessory structure may be located in a required side or rear setback; provided it is more than 100 feet from the front property line or in the rear 25 feet of the site.
From the ordinance