22.364.110.C.4.a
Dimensional standards
Height & bulk
Servicing
- Applies near
- West Rancho Dominguez-Victoria CSD
- Geographic extent
- West Rancho Dominguez-Victoria CSD, All Industrial Zones
Extracted standards
6 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Buffer wall heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.8 ft
Where an industrially zoned lot abuts a residence or residentially zoned lot, landscaped buffer and screening shall be provided, pursuant to Section 22.364.060.E (Landscaped Buffer and Screening), except that the solid masonry wall along the common lot line shall be at least eight feet in height
- Enclosure required
Except as specified otherwise, all uses, except for parking, vending machines, shopping carts, and accessory uses, shall be conducted entirely within a building.
- Front yardYardThe open space left between a building and its lot line — the space a setback creates. landscaping
The required front yard, excluding access, parking, and circulation areas, shall be landscaped, subject to the applicable provisions of Chapter 22.126 (Tree Planting Requirements) and shall be maintained with drought tolerant or low water use, native, or non-invasive plants, grasses, shrubbery, or trees and include an on-site irrigation system such as a drip system.
- HeightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. farFloor area ratio (FAR)Total floor area divided by lot area — an FAR of 2.0 permits 20,000 sq ft of floor on a 10,000 sq ft lot. from residential90 ft
A building or structure located more than 250 feet from a residentially zoned lot shall not exceed a height of 90 feet above grade.
- HeightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. near residential45 ft
A building or structure located within 250 feet of a residentially zoned lot shall not exceed a height of 45 feet above grade.
- Loading dock location
All loading docks shall be located as far distant as feasible from adjoining residentially zoned lots.
From the ordinance
Buildings and structures shall be set back a minimum of ten feet from the front property line.