Los Angeles County Unincorporated, California · General provision

Section 22.322.080

Dimensional standards

Servicing

Applies near
La Brea Avenue
Geographic extent
Oil field portion of the Baldwin Hills CSD, excluding Southern California Edison facility, Holy Cross Cemetery, and small noncontiguous lot east of La Brea Avenue

Extracted standards

7 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Environmental

  • Hydrogen sulfide alarm level5 ppm

    At a hydrogen sulfide concentration equal to or greater than five parts per million, but less than 10 parts per million, the operator shall immediately investigate the source of the hydrogen sulfide emissions and take prompt corrective action to eliminate the source.

  • Total hydrocarbon alarm level500 ppm

    At a total hydrocarbon concentration equal to or greater than 500 parts per million but less than 1,000 parts per million, the operator shall immediately investigate the source of the hydrocarbon emissions and take prompt corrective action to eliminate the source.

Grading

  • Maximum slope gradient2 ratio (2:1)

    No slope of cut or fill shall have a gradient steeper than two to one (2:1), unless specifically approved by a site-specific geotechnical report;

Other

From the ordinance

No surface drilling or other surface oil operations shall be allowed within the portions of this CSD consisting of the Southern California Edison facility, the Holy Cross Cemetery, and the small noncontiguous lot located east of La Brea Avenue.
Section 22.322.080