Los Angeles County Unincorporated, California · General provision

22.320.090.D.4

Dimensional standards

Extracted standards

17 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Design

  • Neon color maximum20 pct

    The use of neon colors shall be limited to architectural accent features and not exceed 20 percent of a building frontage surface

Height

Other

  • Encroachment plane angle45 deg

    A 45-degree encroachment plane shall be required for new construction. The encroachment plane shall extend from a six-foot height at the edge of the required landscaped buffer

  • Landscaped buffer5 ft

    A five-foot landscaped buffer shall be provided.

  • the total gross floor area of a lot shall not exceed 1.8 times the total area of such lot.

  • Window coverage area40 pct

    At least 55 percent of the total length and 40 percent of the total area of the façade of the building on the ground floor shall be devoted to windows, interior views, or interior displays

  • Window coverage width55 pct

    At least 55 percent of the total length and 40 percent of the total area of the façade of the building on the ground floor shall be devoted to windows, interior views, or interior displays

Parking

  • Parking requirements

    Automobile parking shall be provided in accordance with Chapter 22.112 (Parking) and comply with current requirements for accessible parking for people with disabilities, except that the following requirements shall apply: Table 22.320.090-G

Signage

From the ordinance

Except in the Lake Avenue Mixed Use 'Center' Area, the maximum height for any commercial structure shall be 35 feet, except that a portion or portions of the building, not to exceed a total 20 percent of the building footprint, may be up to three stories or 45 feet in height