22.364.080.C.2
Dimensional standards
Servicing
- Applies near
- East Los Angeles
- Geographic extent
- East Los Angeles CSD - All Zones
Extracted standards
13 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Awning repair timeframe30 days
Awnings in disrepair shall be repaired or removed within 30 days after receipt of notification
- Maximum decorative concrete block percentage50 pct
Decorative concrete blocks shall be limited to a maximum of 50 percent of the street façade.
- Minimum durable material heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.2 ft
Concrete, masonry, natural stone, or other durable material shall be used for wall surfaces within two feet above grade of the street façade.
- Facade articulation requirement
Each building or portions of a building, with more than one story, shall have, at a minimum, a distinctive building base, building middle, and building top (eave, cornice, and/or parapet line)
- Graffiti resistant coating
Any blank exterior wall shall also be treated with a graffiti-resistant coating.
- Maximum reflective glass percentage20 pct
Mirrored, highly reflective glass or densely tinted glass shall not be used, except as an architectural or decorative accent totaling a maximum of 20 percent of the building façade.
- Minimum awning clearance8 ft
Clearance: Minimum eight feet in height from the base of the awning.
- Minimum awning depth4 ft
Depth: Minimum four feet
- Minimum ground floor pedestrian interest65 pct
At least 65 percent of the total width of the building's ground floor parallel to and facing the street shall be devoted to entrances, shop windows, or other displays
- Minimum ground floor pedestrian interest30 pct
At least 30 percent of the total width of the building's ground floor parallel to and facing the street shall be devoted to entrances and windows.
- Minimum window inset3 in
Glass shall be recessed or projected at least three inches from the exterior wall surface
- Maximum stucco percentage50 pct
be trimmed or combined with wood, masonry, or other durable material and be limited to a maximum of 50 percent of the street façade
- Minimum stucco heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. above grade2 ft
Not extend below two feet above grade of the street façade.
From the ordinance
Each building or portions of a building, with more than one story, shall have, at a minimum, a distinctive building base, building middle, and building top