12 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Parking
- Additional long-term bicycle parking spaces2 spaces
A minimum of eight additional short-term, and two additional long-term, bicycle parking spaces shall be provided on-site for the general public.
- Additional short-term bicycle parking spaces8 spaces
A minimum of eight additional short-term, and two additional long-term, bicycle parking spaces shall be provided on-site for the general public.
- Garage access from primary corridor restriction
Residential garage access is not allowed from any Primary Corridor unless no other feasible option is available.
- Individual unit garage setbackSetbackThe distance a building must be held back from a lot line.3 ft
Provide a three-foot minimum setback or greater than 18 feet for individual unit garages.
- Maximum curb cuts per street frontageFrontageThe length of a lot line that touches a public street.1 count
Developments are allowed a maximum of one curb cut per street frontage per property.
- Maximum driveway width per 100 feet of frontageFrontageThe length of a lot line that touches a public street.20 ft
Not more than 20 feet of a property frontage shall be devoted to parking access, such as driveways, for every 100 feet of lot frontage.
- Maximum street-facing garages1 count
Street-facing garages shall be limited to a maximum of one garage serving a maximum of two cars for any project with four or more units.
- Off-site parking distance1,500 ft
Parking requirements for non-residential uses may be met within 1,500 feet from the site of the development.
- Oversize vehicle parking location
Parking for vehicles that exceed 20 feet in length or nine feet in width shall be located as far as possible from any abutting residentially-zoned lots.
- ProhibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. driveway width range
Driveway widths between three feet and 18 feet are not allowed.
- Shared garage access setbackSetbackThe distance a building must be held back from a lot line.3 ft
Provide a minimum three-foot setback for shared garage access.
- Unbundled parking required
Where parking is voluntarily provided, unbundled parking is required for residential units in the TOD Mixed Use Zones.
From the ordinance
Except as specified otherwise by State law, the standards for parking requirements contained in Chapter 22.112 (Parking) shall apply to all development in the Specific Plan Area with the following modifications.