Section 22.140.560
Dimensional standards
Extracted standards
9 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Fencing & walls
- Minimum fence heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. when adjoining residential6 ft
When the facility adjoins a residentially zoned property, a masonry or decorative block wall at least six feet in height shall be constructed along the property lines.
Landscaping & trees
- Tree planting rate1 trees per 20 ft
for every 20 feet of street frontage of the subject property, a minimum of one 24-inch boxed tree shall be planted and continuously maintained.
Lighting
- Maximum lighting intensity1 foot-candle
Such lighting should not exceed an intensity of one foot-candle of light throughout the facility.
Other
- Maximum access points per side1 points
Vehicular ingress and egress shall be limited to one point for each side of the subject property adjoining any street or highway, and shall conform to the Fire Department standards.
- Maximum outdoor storage heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.15 ft
Any vehicle or piece of equipment stored shall not be permitted to exceed 15 feet in height, as measured from grade.
- Minimum driveway depth40 ft
At least 40 feet of clear, unobstructed driveway depth shall be provided from the road to the primary access gate or principal entry point of the facility.
- Minimum interior driveway width26 ft
Interior driveway widths shall be at least 26 feet unless, due to the irregular shape or configuration of the lot under consideration, the Commission or Hearing Officer specifically authorizes a width less than 26 feet, if in conformity with Fire Department standards. A driveway providing access to storage units on one side only of the facility shall be not less than 20 feet in width.
- Resident manager required
A resident manager shall be required at the facility, housed in a structure with an architectural style and exterior finish compatible with the other buildings on the subject property.
- Trash receptacle requirement
One four-cubic-yard trash receptacle and surrounding enclosure shall be provided as follows: Between 0 to 60,000 gross square feet, one receptacle. Over 60,000 gross square feet, two receptacles.
From the ordinance
The minimum lot size shall be one acre, unless the Commission or Hearing Officer approves a smaller lot. Total lot coverage by buildings shall not exceed 50 percent.
Parking requirements
{
"general": "1 space per 7,000 sqft GFA",
"manager": "2 covered spaces",
"employee": "1 space per employee"
}