22.44.1270
Dimensional standards
Height & bulk
Servicing
- Geographic extent
- Coastal Zone
Extracted standards
5 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Lighting
- ProhibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. lighting types
Drop-down lenses, mercury vapor lights, ultraviolet lights, searchlights, laser lights, flashing/blinking/alternating/moving lights, sports court lighting, athletic field lighting, perimeter lighting, driveway/access road lighting, equestrian pasture lighting.
- Maximum output for residential fixtures above 15 feet40 watts
For properties located in a R-C, R-1, R-3, R-R, O-S or OS-P zone, outdoor light fixtures installed more than 15 feet above finished grade shall have a manufacturer's maximum output rating of no greater than 40 watts (400 lumens).
- Maximum security lighting output60 watts
Security lighting attached to the principally permitted structure and other permitted accessory structures that is controlled by motion detectors and shall have a manufacturer's maximum output rating of no greater than 60 watts (600 lumens), or the equivalent.
- Shielding requirement
Outdoor lighting shall be fully shielded, directed downward, and use best available dark skies technology.
- Maximum walkway lighting heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.2 ft
This lighting shall be limited to fixtures that do not exceed two feet in height, that are directed downward, and have a manufacturer's maximum output rating of no greater than 60 watts (600 lumens), or the equivalent.
From the ordinance
Exterior lighting (except traffic lights, navigational lights, and other similar public safety lighting) shall be minimized, restricted to low-intensity features, shielded, and concealed to the maximum feasible extent using the best available dark skies technology