22.44.1250.B
Dimensional standards
Height & bulk
Servicing
- Geographic extent
- Coastal Zone
Extracted standards
4 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Height
- Maximum building heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.30 ft
every residence and every other building or structure in the Coastal Zone shall have a height not to exceed 30 feet above natural or finished grade, whichever is lower
- Maximum building heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. with smaller footprint35 ft
Where an applicant can demonstrate that a taller structure would result in a smaller building footprint with less land alteration and fewer impacts to environmental resources, for example on a downslope development, a building or structure shall not exceed 35 feet above natural or finished grade, whichever is lower.
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for chimneys, solar panels, antennas6 ft
Chimneys, rooftop solar panels and rooftop antennas may extend a maximum six feet above the permitted height of the structure.
- Maximum building heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. in Scenic Resource Area18 ft
Every residence and every other building or structure in a Scenic Resource Area, shall have a height not to exceed 18 feet above natural or finished grade, whichever is lower
From the ordinance
every residence and every other building or structure in the Coastal Zone shall have a height not to exceed 30 feet above natural or finished grade, whichever is lower