Los Angeles County Unincorporated, California · General provision

22.22.090

Dimensional standards

lot requirementsSTREETMIN LOT AREA5 acMAX FAR1
Plan view of the district’s stated lot requirements. Solid line: the property line. Dashed: the setback lines the ordinance imposes; a building must stay inside the tinted envelope. Drawn from the figures extracted below — illustrative, not a survey.

Uses

Permitted by right1

  • Any nonresidential use permitted in Zone R-A, subject to the same limitations and conditions

Conditional / special use2

  • A planned industrial development in which the Commission or Hearing Officer may approve any use permitted in Zone M-1.5
  • Child care centers

Prohibited1

  • Oil wells and production facilities, in accordance with Section 22.140.400

Extracted standards

3 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Design

  • Design compatibility required

    Structural improvements shall not detract from the established or anticipated character of the surrounding area.

Other

  • Maximum ground-floor area percentage60 pct

    The ground-floor area of buildings shall not exceed 60 percent of the gross area of the lot.

  • Underground utilities required

    Applicant shall make arrangements with serving utilities to install underground all new facilities necessary to furnish service in the development.

From the ordinance

Planned industrial development shall include a minimum lot area of five acres; FAR not greater than 1.0; ground-floor area not exceed 60% of gross lot area.
22.22.090