Sec. 86-614
Extracted standards
9 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Digital copy in DXF
The engineer/surveyor shall provide the county with a digital copy of the subdivision plat in DXF file.
- Final plat accuracy10,000 ratio
Distances and bearings must balance and close with an accuracy of not less than one in 10,000.
- Final plat scale100 ft/inch
The subdivision plat submitted for final approval by the agent or planning commission and subsequent recording shall be clearly and legibly drawn in ink at a scale of 100 feet to the inch
- FloodplainFloodplainLand expected to flood at a stated frequency, where building carries extra conditions. mapping requirement
A 100-year floodplain, as defined by FEMA, shall be shown on the final subdivision plat whenever a drainage way with a contributing watershed of 50 acres or greater falls within the limits of a proposed subdivision.
- Private road disclosure
All plats, contracts of sale and deeds for a lot in a subdivision with a new internal subdivision street shall contain the following language which clearly discloses to a potential purchaser the following minimum information: ...
- Right-of-way dedication only note
Where a final plat submitted under section 86-587 (location) proposes no improvements other than those covered under VDOT's Lot Entrance Permit Application and solely provides for the dedication of right-of-way sufficient to achieve a 50-foot total width along an existing public road, such plat shall not require review or approval from the Virginia Department of Transportation (VDOT) prior to approval by Louisa County. A plat note shall be included stating: "Right-of-way dedication only; no improvements proposed other than those covered under VDOT's Lot Entrance Permit Application. VDOT entrance permit required prior to zoning or building permit issuance."
- Septic reserve area100 pct
Location of an adequate building site, proposed drain field and 100 percent reserve area for septic or alternative wastewater systems as approved by the state department of health.
- Septic system type note
The final plat shall include a note identifying if the proposed drain field and 100 percent reserve area required for each lot, in subsection (13) above, is approved as a conventional or alternative system.
- VDOT entrance permit note
All plats must contain a note stating, "Entrance locations to each lot shown on this subdivision plat require approval by the Virginia Department of Transportation (VDOT) at the time the entrance permit is applied for through VDOT."
From the ordinance
The subdivision plat submitted for final approval by the agent or planning commission and subsequent recording shall be clearly and legibly drawn in ink at a scale of 100 feet to the inch, or the discretion of the agent, on sheets having such size or dimensions as the clerk of the court wherein deeds are recorded shall, upon request of the subdivider or his certified surveyor or engineer, from time to time direct, so that the plat may conform or be recorded in his then current plat book without folding, cutting or trimming, and shall include the following: