Chesapeake
Zoning districts
19 districts, grouped by category.
Agricultural
1Commercial
3Neighborhood Business District
- Min lot
- 15,000 sq ft (0.34 ac)
- Max height
- 75 ft
- Front setback
- 30 ft
- Permitted uses
- 3
General Business District
- Min lot
- 15,000 sq ft (0.34 ac)
- Max height
- 75 ft
- Front setback
- 35 ft
- Permitted uses
- 4
Urban Business District
- Max height
- 35 ft
- Front setback
- 5 ft
- Permitted uses
- 2
Other
3Industrial
3Light Industrial District
- Min lot
- 2,178,000 sq ft (50 ac)
- Permitted uses
- 8
Heavy Industrial District
- Min lot
- 2,178,000 sq ft (50 ac)
- Permitted uses
- 10
Waterfront Industrial District
- Min lot
- 15,000 sq ft (0.34 ac)
- Max height
- 75 ft
- Front setback
- 25 ft
- Permitted uses
- 3
Open space
5Residential
4R-10
- Min lot
- 10,000 sq ft
- Max height
- 35 ft
- Front setback
- 25 ft
- Permitted uses
- 2
R-6 Residential District
- Min lot
- 6,000 sq ft
- Max height
- 35 ft
- Front setback
- 20 ft
- Permitted uses
- 1
R-8
- Min lot
- 8,000 sq ft
- Max height
- 35 ft
- Front setback
- 25 ft
- Permitted uses
- 2
Residential Estate District
General provisions
588 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.
For property located partially or wholly within the Fentress Airfield overlay district, the final site plan shall contain a statement as follows: 'This development is located partially or wholly within an aircraft noise and/or accident zone and may be subject to above average noise levels or to aircraft accidents.'
For property located partially or wholly within the Fentress Airfield overlay district, the final site plan shall contain a statement as follows: "This development is located partially or wholly within an aircraft noise and/or accident zone and may be subject to above average noise levels or to aircraft accidents."
Where a site plan is required under this zoning ordinance for the construction or structural alteration of any building or structure or the development or modification of any land, no building permit shall be issued for such activity until the required site plan has been approved.
Lot frontage shall be measured along the street reservation line... minimum of 80 percent of the minimum lot width... minimum lot frontage for lots used exclusively for storm water management, open space or conservation shall be fifty (50) feet.
Each required yard abutting a street shall be measured from the street reservation line... Where no reservation line exists... measured from a line located twenty-five (25) feet from the centerline of the pavement.
On a corner lot no fence, wall, hedge or other planting or structure that will obstruct vision between a height of two and one-half feet and ten feet above the pavement centerline grades... within triangular area... points which are forty-five (45) feet from the point where the projections of the pavement edges intersect.
The height limitations set out elsewhere in this zoning ordinance shall not apply to chimneys, church spires, belfries, cupolas... Mechanical equipment located on a roof shall be hidden by a wall or other similar enclosure extending not more than one foot above the height of such equipment.
Within the urban overlay district and as part of an application for a change in the zoning district classification... city council may approve a reasonable deviation from one or more of the following requirements: required yards and setbacks; required landscaping; height restrictions; minimum lot frontage, width, and size; and maximum lot coverage.
Every development shall be required to install public improvements in accordance with the requirements of chapter 70 of the city Code.
Stacking lanes shall be provided to accommodate at least five (5) vehicles... Off-street parking spaces shall be provided on the same lot... no parking space shall be located farther than five hundred (500) feet... All lighting used to illuminate parking areas shall be arranged... does not exceed 0.5 footcandles above background... an off-street parking space shall be considered to consist of an identified and marked space of at least nine (9) feet by eighteen (18) feet.
The number of parking spaces required for developments in the O&I, AC, B-1, B-2, M-1 and M-2 zoning districts shall be one (1) parking space for every two hundred (200) square feet of gross floor area devoted to office space, customer service or retail sales and one-half (.5) parking space for every one thousand (1,000) square feet of remaining gross floor area.
The number of parking spaces required for developments in the O&I, AC, B-1, B-2, M-1 and M-2 zoning districts shall be one (1) parking space for every two hundred (200) square feet of gross floor area devoted to office space, customer service or retail sales and one-half (.5) parking space for every one thousand (1,000) square feet of remaining gross floor area.
A loading space shall have minimum plan dimensions of twelve (12) feet by thirty-five (35) feet, with fourteen (14) feet overhead clearance.
The maximum building height in the R-MF-1 and R-MF-2 zoning districts may only be adjusted according to the following: a. The maximum building height may be adjusted to allow one additional story. b. No adjustment to the maximum building height under this section shall result in a structure higher than forty-five (45) feet
The maximum building height in the R-MF-1 and R-MF-2 zoning districts may only be adjusted according to the following: a. The maximum building height may be adjusted to allow one additional story. b. No adjustment to the maximum building height under this section shall result in a structure higher than forty-five (45) feet
It is the intent of this ordinance that the entire incorporated area of the city of Chesapeake, including all land, water areas and waterways, be included in the zoning districts established by this ordinance. Any area not shown on the official zoning map as being included in any district shall be deemed to be in the C-1 conservation district.
Unless otherwise specified, all distances shall be measured horizontally and at right angles to the line in relation to which the distance is specified.
Numbers which are less than five-tenths (0.5) of a whole number shall be rounded to the next lower whole number. Numbers which are five-tenths (0.5) or more of a whole number shall be rounded to the next higher whole number.
private access lanes, storm water management and certain septic drain fields may be located in any zoning district subject to the requirements set out below
All private access lanes must be approved by a conditional use permit
Source documents
The chapters of the adopted code that were retrieved, read and extracted from. Everything above traces back to one of these.
- Chapter 110.7K charsRead →
- Chapter 10112.5K charsRead →
- Chapter 1174K charsRead →
- Chapter 1297.8K charsRead →
- Chapter 13167.7K charsRead →
- Chapter 14321.6K charsRead →
- Chapter 15467.5K charsRead →
- Chapter 16370.1K charsRead →
- Chapter 1774.7K charsRead →
- Chapter 18126.6K charsRead →
- Chapter 1957.3K charsRead →
- Chapter 213.6K charsRead →
- Chapter 2079K charsRead →
- Chapter 21265.1K charsRead →
- Chapter 2294.3K charsRead →
- Chapter 2357.4K charsRead →
- Chapter 328.2K charsRead →
- Chapter 49.2K charsRead →
- Chapter 5149.2K charsRead →
- Chapter 635.3K charsRead →
- Chapter 738.6K charsRead →
- Chapter 8284.9K charsRead →
- Chapter 9199.4K charsRead →