County (unincorporated) · Virginia

Loudoun County Unincorporated

This locality is on the roster but its ordinance has not been retrieved yet.
22
Districts
931
Extracted rules
2,878
Standards
14
Chapters read
Zoning snapshotNot yet acquired

Zoning districts

22 districts, grouped by category.

Residential

15
R-1Residential

Single-Family Residential R-1 Legacy Zoning District

Loudoun County Unincorporated, VA
Min lot
40,000 sq ft (0.92 ac)
Permitted uses
1
R-16Residential

R-16 Townhouse/Multifamily Legacy Zoning District

Loudoun County Unincorporated, VA
Max height
40 ft
Front setback
25 ft
Max density
16 du/ac
Permitted uses
3
R-2Residential

Single-Family Residential R-2 Legacy Zoning District

Loudoun County Unincorporated, VA
Min lot
20,000 sq ft (0.46 ac)
Permitted uses
2
R-24Residential

Multifamily Residential R-24 Legacy Zoning District

Loudoun County Unincorporated, VA
Max height
45 ft
Front setback
25 ft
Max density
24 du/ac
Permitted uses
1
R-3Residential

Single-Family Residential R-3 Legacy Zoning District

Loudoun County Unincorporated, VA
Min lot
15,000 sq ft (0.34 ac)
Permitted uses
2
R-4Residential

Single Family Residential R-4 Legacy Zoning District

Loudoun County Unincorporated, VA
Min lot
10,000 sq ft
Max height
40 ft
Front setback
25 ft
Max density
4 du/ac
Permitted uses
2
R-8Residential

Single Family Residential R-8 Legacy Zoning District

Loudoun County Unincorporated, VA
Max height
40 ft
Front setback
15 ft
Max density
8 du/ac
Permitted uses
6
SCN-16Residential

Suburban Compact Neighborhood - 16

Loudoun County Unincorporated, VA
Max height
50 ft
Permitted uses
40
SCN-24Residential

Suburban Compact Neighborhood - 24

Loudoun County Unincorporated, VA
Max height
50 ft
Permitted uses
41
SCN-8Residential

Suburban Compact Neighborhood - 8

Loudoun County Unincorporated, VA
Max height
50 ft
Front setback
15 ft
Permitted uses
47
SN-4Residential

Suburban Neighborhood - 4

Loudoun County Unincorporated, VA
Max height
50 ft
Front setback
15 ft
Permitted uses
51
SN-6Residential

Suburban Neighborhood - 6

Loudoun County Unincorporated, VA
Max height
50 ft
Permitted uses
49
TR-1Residential

Transitional Residential-1

Loudoun County Unincorporated, VA
Max height
40 ft
TR-2Residential

Transitional Residential-2

Loudoun County Unincorporated, VA
Max height
35 ft
Front setback
10 ft
TR-3Residential

Transitional Residential-3

Loudoun County Unincorporated, VA

General provisions

909 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.

Section 4.06.01.B.11 standards

All associated activities must be contained within a building. No outdoor storage of materials is allowed.

Section 4.06.01.B.21 standards

Outdoor storage in conjunction with the use is subject to the Use-Specific Standards of Section 4.06.07.

Section 4.06.01.B.31 standards

Contractors with no outdoor storage are permitted. Contractors with outdoor storage require Special Exception approval and such outdoor storage is subject to the Use-Specific Standards of Section 4.06.07.A-G.

Section 4.06.01.B.42 standards

Up to 20% of the gross lot area may be used for outdoor storage in conjunction with a contractor use, subject to the Use-Specific Standards of Section 4.06.07.A-F. Outdoor storage greater than 20% of the gross lot area requires Special Exception review and approval.

Section 4.06.0213 standards

Data centers must meet the Façade Standards in Section 4.06.02.C and the General Site Design Standards in Section 4.06.02.D.

Section 4.06.02.C.1.b.3.a5 standards

Fenestration must comprise at least 30% of the total surface coverage area of the Principal Façade.

Section 4.06.02.D.11 standards

Loading bays are permitted to be located on only 1 façade.

Section 4.06.02.D.102 standards

Data Centers are subject to the Noise Study standards pursuant to Section 7.05.03.G. For Data Centers on property adjacent to property with existing residential development... any Data Center Mechanical Equipment located on the property... must be screened on all four sides by an acoustical barrier.

Section 4.06.02.D.118 standards

A maximum of 20% of the required plant units may be a combination of shrubs, ornamental grasses, and perennials. A minimum of 40% and a maximum of 70% of the required plant units must be evergreen trees that are a minimum of 8 feet in height at the time of planting. A maximum of 30% of the required plant units may be small deciduous trees. A maximum of 30% of the required plant units may be large deciduous trees.

Section 4.06.02.D.22 standards

All ground level and roof top Data Center Mechanical Equipment must meet the following standards: Data Center Mechanical Equipment must be shown on any proposed Site Plan and must be fully screened on all sides.

Section 4.06.02.D.31 standards

Refuse collection areas must be fully screened on all sides and loading bays must be screened from view at the ground level from all adjacent parcels and existing or planned public roads.

Section 4.06.02.D.74 standards

Parking must be setback at least 50 feet from the common property line... Structures must be setback at least 200 feet from the common property line.

Section 4.06.02.D.83 standards

Generator testing is limited to between 5:00 p.m. and 7:00 p.m. between May 1 and September 30; Generator testing is limited to between 11:00 a.m. and 5:00 p.m. between October 1 and April 30; Except for generator testing or commissioning activities, generator use is limited to backup/emergency use only.

Section 4.06.02.D.91 standards

Data Centers must include a photometric plan that shows all exterior lighting, including any security lighting; and Maximum illumination under Section 7.05.02.B.3 includes any security lighting.

Section 4.06.039 standards

Stone quarrying uses must meet the following additional Use-Specific Standards...

Section 4.06.03.C.15 standards

The pit wall of a quarry must be set back at least 1,000 feet from the MR-HI Zoning District boundary

Section 4.06.03.C.22 standards

Structures enclosing processing equipment associated with an extraction operation, including crushers, conveyors, washers, and screeners, must be set back a minimum of 500 feet from the MR-HI Zoning District boundary

Section 4.06.03.C.33 standards

Other structures related to extraction operations, including scale houses and storage yards, must be set back as follows: A minimum of 200 feet from the MR-HI Zoning District boundary. Exception. When abutting the GB, CLI, or GI Zoning District boundary, the minimum setback from the MR-HI Zoning District boundary is 50 feet; and A minimum of 100 feet from all public roads within the zoning district.

Section 4.06.03.C.41 standards

Buildings devoted solely to office and administrative uses must be set back a minimum of 50 feet from the MR-HI Zoning District boundary.

Section 4.06.03.C.51 standards

For adjacent properties, no commercial, industrial, or other nonresidential building is allowed within 50 feet from the property line of an existing and/or approved quarry operation.

Source documents

The chapters of the adopted code that were retrieved, read and extracted from. Everything above traces back to one of these.