M-1
Dimensional standards
Uses
Permitted by right24
- manufacturing
- day care center
- agriculture
- horticulture
- forestry
- cabinet shop
- furniture shop
- upholstery shop
- recording studio
- monumental stone works
- public utility facilities
- mini-warehouse
- wholesale business
- storage warehouse
- office
- laboratory
- pharmaceutical use
- medical use
- commuter parking lot
- conference center
- training center
- auto body repair
- telecommunications tower (attached)
- solar energy facility (minor-scale, roof-mounted)
Conditional / special use31
- transitional use (B-1/B-2 uses)
- truck terminal
- truck complex
- telecommunications tower (freestanding)
- coal yard
- wood yard
- civic meeting place
- social meeting place
- fraternal meeting place
- fitness facility
- dance lessons
- sport skills facility
- hotel
- motel
- hospital
- water treatment plant
- sewerage treatment plant
- utility substation
- bank
- financial institution
- contractor service establishment
- public recycling collection point
- outdoor recreation establishment
- government building
- government function
- individual well
- septic system
- heavy vehicle repair
- heliport
- materials recovery facility
- solar energy facility (minor-scale, ground-mounted)
Extracted standards
6 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Height
- HeightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. special exception
Buildings over 45 ft may be permitted by special exception with increased setback of 5 ft per additional foot.
Noise
- Noise compliance
Noise levels shall comply with Article II Noise of the Noise Ordinance.
Other
- Access restriction
Lot access shall not be provided through contiguous residential districts, residential areas of planned districts, or residential subdivisions in A-1 or RR districts.
25 ft if parking behind building, screened, or increased landscaping; otherwise 80 ft plus distance of impervious surfaces.
- Enclosed operations
All manufacturing operations must take place within a completely enclosed building unless special exception granted.
- Minimum districtZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2. area10 acresacre43,560 square feet — about the size of an American football field without the end zones.
Minimum district area: 10 acres, reducible to 3 acres with special exception.
From the ordinance
M-1 Industrial District: Permitted uses, special exceptions, lot requirements, building requirements, use limitations.