Municipality · California

Rancho Palos Verdes

The ordinance has been retrieved, read and turned into structured rules.
15
Districts
339
Extracted rules
1,229
Standards
8
Chapters read

Zoning districts

15 districts, grouped by category.

General provisions

324 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.

17.76.170

The director of planning, building and code enforcement shall consult with the floodplain administrator (director of public works) to determine whether an application proposes new construction or other development within a floodprone area

17.76.1808 standards

Cargo containers shall not be stored, maintained, or otherwise kept on any property within the city except as follows... Cargo containers shall be set back a minimum five feet from any property line and a minimum ten feet from any structure. Any permitted cargo container shall not exceed a height of eight feet and six inches, a width of eight feet, and a length of 40 feet.

17.76.1806 standards

Cargo containers shall not be stored, maintained, or otherwise kept on any property within the city except as follows: ...

17.76.180(E)4 standards

For parcels within the most continuously and actively moving portion of the Greater Portuguese Bend Landslide Complex ... the use of one cargo container per developed parcel for storage may be permitted through a special use permit application...

17.76.1905 standards

The minimum size of a single-room occupancy unit shall be 150 square feet and the maximum size shall be 220 square feet... One parking space for every two units shall be provided, with a minimum of two parking spaces for the entire facility.

17.76.1909 standards

The minimum size of a single-room occupancy unit shall be 150 square feet and the maximum size shall be 220 square feet...

17.83.0503 standards

Installation of renewable energy systems are permitted in any zoning district through a minor site plan review application, provided that such systems do not encroach into a setback area or exceed 12 feet in height, as measured from existing grade.

17.83.0503 standards

Installation of renewable energy systems are permitted in any zoning district through a minor site plan review application, provided that such systems do not encroach into a setback area or exceed 12 feet in height...

17.83.0608 standards

No small wind energy system shall be constructed, installed, or modified without first obtaining a conditional use permit... The height of the tower and wind turbine shall not exceed the manufacturer's recommended height for the system, and in no event shall the total height exceed 100 feet as measured from the ground surface at the base of the tower to the highest point of the wind turbine blade in its vertical position.

17.83.0609 standards

The installation and/or operation of a small wind energy system ... shall require a conditional use permit...

17.83.06016 standards

A small wind energy system may be permitted in any zoning district subject to the issuance of a conditional use permit... The total height... shall not exceed 80 feet... The tower shall be set back... a distance equal to 1.5 times the total height...

17.84.0402 standards

All lots which do not meet the minimum lot area, dimension standards and minimum building pad area requirement of the district in which they are located are deemed nonconforming lots, and the following provisions shall apply:

17.84.0401 standards

All lots which do not meet the minimum lot area, dimension standards and minimum building pad area requirement of the district in which they are located are deemed nonconforming lots, and the following provisions shall apply: A. Undeveloped, nonconforming lots may be used and have a structure erected upon them, provided that geologic and/or soils reports are submitted and approved by the city and all applicable building code requirements can be satisfied.

17.84.0401 standards

No nonconforming lot shall be reduced in area or dimensions if such reduction would result in a greater degree of nonconformity.

17.84.0501 standards

No nonconforming use shall be expanded or moved in whole or in part to any portion of the lot or parcel or other structure other than that occupied by such use at the effective date

17.84.0501 standards

If a nonconforming use is discontinued for a period of 180 calendar days or more, it shall not be reestablished.

17.84.0501 standards

No nonconforming use shall be expanded or moved in whole or in part to any portion of the lot or parcel or other structure other than that occupied by such use at the effective date of the ordinance from which the provisions of this chapter are derived, except as provided in sections 17.12.040 (Commercial Districts) and 17.26.050 (Institutional (I) District) of this title.

17.84.0501 standards

No nonconforming use may be changed to a different nonconforming use.

17.84.0602 standards

No physical change, enlargement, extension or reduction which increases the degree or extent of a nonconforming structure or building shall be made.

17.84.0601 standards

Residential buildings that are proposed to be remodeled or renovated such that 50 percent or greater of any existing interior and exterior walls or existing square footage is demolished or removed within a two-year period, shall then conform to all current development standards for that district

Source documents

The chapters of the adopted code that were retrieved, read and extracted from. Everything above traces back to one of these.