Sussex County Unincorporated, Virginia · General provision

Sec. 34-195

Extracted standards

5 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Lighting

  • Parking lighting glare control

    Any lighting equipment should be designed and arranged so as to direct light and glare away from abutting properties and adjacent rights-of-way.

Other

  • Fire lane minimum width18 ft

    Fire lanes shall be a minimum of 18 feet in width and shall be marked for case of visibility as required by the fire marshal.

  • Loading space dimensions12 ft

    Each off-street loading space shall be not less than 12 feet by 50 feet in dimensions with a vertical clearance of not less than 15 feet.

Parking

From the ordinance

In any district, all structures erected or enlarged and all uses established or expanded, shall provide off-street parking and loading in accordance with the requirements established herein.
Sec. 34-195

Parking requirements

{
  "hotels": "1 per 2 rooms up to 20, then 1 per 3 rooms over 20",
  "assembly": "1 space per 5 fixed seats",
  "hospitals": "1 space per 2 beds + 1 per employee on largest shift",
  "residential": "1 space per dwelling unit",
  "restaurants": "1 per 100 sq ft floor space",
  "other_industrial": "1 per 500 sq ft or per 3 employees (whichever greater) + 1 per vehicle",
  "tourist_homes_motels": "1 space per accommodation + 1 per employee, min 2 additional",
  "medical_dental_clinics": "10 spaces + 3 per doctor/dentist over 3",
  "mini_storage_warehouse": "1 per 10 cubicles + 2 for manager + 1 per 25 cubicles",
  "other_commercial_public": "1 per 200 sq ft floor space",
  "mortuaries_liquor_stores": "30 spaces",
  "warehousing_distributing": "1 per 1000 sq ft + 1 per 300 sq ft office + 1 per vehicle",
  "tourist_courts_apartments": "1 space per sleeping/living unit"
}