Rockingham County Unincorporated, Virginia · General provision

Wind Energy Systems, Small-Scale

Extracted standards

4 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Height

Noise

  • Maximum noise level60 dB

    Small wind energy systems shall not exceed sixty (60) decibels, as measured at the closest property line; however, the level may be exceeded during short-term events such as severe windstorms.

Other

  • Fence or non-climbable base

    The supporting wind energy tower shall also be enclosed with a six-foot tall fence or the base of the wind energy tower shall not be climbable for a distance of twelve (12) feet.

  • Minimum distance between ground and blades15 ft

    The minimum distance between the ground and any protruding blades utilized on a small wind energy system shall be fifteen (15) feet, as measured at the lowest point of the arc of the blades.

From the ordinance

The wind energy tower height shall not exceed a maximum height of sixty-five (65) feet on a parcel of less than five (5) acres, or a maximum height of eighty (80) feet on a parcel of five (5) acres or more.
Wind Energy Systems, Small-Scale