Sec. 17-706
Dimensional standards
Servicing
- Geographic extent
- Applies to all zoning districts
Extracted standards
6 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Lighting
- Canopy lighting recessed and shielded
Canopy lighting shall be recessed and/or shielded so that all light emitted is projected directly beneath the canopy and not beyond it.
- IDA approval or full cut-off design required
All new lighting fixtures shall be approved by the International Dark-Sky Association (IDA), or equivalent. Lighting fixtures not approved by the IDA shall be full cut-off design.
- Light directed downward
Lighting fixtures shall be installed in a fixed position which orients the light downward.
- Lighting turned off after business hours
All outdoor lighting, including display lighting, shall be turned off after the close of business hours, except that needed for safety and security
- Maximum illumination at property line0.5 fc
Lighting fixtures shall provide only 0.5 footcandle maximum at the property line.
- Photometric plan required
A photometric plan shall be included with all engineered site plans where these fixtures are proposed
From the ordinance
Lighting fixtures shall provide only 0.5 footcandle maximum at the property line.