Design

  • Monopole design required

    Wind energy system towers shall be of monopole design and shall be painted a non-reflective unobtrusive color.

Lighting

  • Artificial lighting restriction

    Wind energy system towers shall not be artificially lighted unless required by the FAA or appropriate authority.

Noise

  • Maximum audible sound level60 dB

    Audible sound from a wind energy system shall not exceed sixty (60) decibels, as measured from any adjacent non-participating landowners' property line.

Other

From the ordinance

The minimum lot size for a utility scale wind energy system shall be five (5) acres per turbine. The individual turbines shall not exceed six hundred eighty (680) feet in height. Wind turbines, post construction meteorological towers and other associated towers shall be set back a distance at least equal to one hundred ten (110) percent of its total height from all adjacent non-participating landowner's property lines and a distance equal at least to one hundred fifty (150) percent of its total height from the nearest occupied building on a non-participating landowner's property. Audible sound from a wind energy system shall not exceed sixty (60) decibels, as measured from any adjacent non-participating landowners' property line.