Sec. 25-446(d) and (e)
Dimensional standards
Height & bulk
Servicing
- Applies near
- A-1 and FC districts
- Geographic extent
- Applies in AgriculturalAgricultureRaising crops or livestock, generally including the structures that serve them. Use DistrictZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2. (A-1) and Forest Conservation Use DistrictZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2. (FC)
Extracted standards
7 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Lighting
- Artificial lighting restriction
A temporary meteorological tower shall not be artificially lighted unless required by the FAA or appropriate authority.
Other
- Maximum permit duration24 months
Any approved permit shall be valid for a period that does not exceed twenty-four (24) months.
- Minimum lot size for by-rightBy rightPermitted outright: if the plans meet the written rules, permission cannot be withheld. MET5,000 acresacre43,560 square feet — about the size of an American football field without the end zones.
No temporary meteorological tower shall be permitted by right on a lot or parcel smaller than five thousand (5,000) acres in size.
- Minimum lot size for special exception MET2 acresacre43,560 square feet — about the size of an American football field without the end zones.
No temporary meteorological tower shall be located on a lot or parcel smaller than two (2) acres in size.
- SetbackSetbackThe distance a building must be held back from a lot line. from nearest occupied building on non-participating landowner's property (percent of heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.)150 pct
or a distance at least equal to one hundred fifty (150) percent of its total height from the nearest occupied building on a non-participating landowner's property.
- SetbackSetbackThe distance a building must be held back from a lot line. from property line (by rightBy rightPermitted outright: if the plans meet the written rules, permission cannot be withheld., percent of heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.)400 pct
A temporary meteorological tower shall be setback a distance at least equal to four hundred (400) percent of the total structure height from any property line.
- SetbackSetbackThe distance a building must be held back from a lot line. from property line (special exception, percent of heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.)110 pct
A temporary meteorological tower shall be setback a distance at least equal to one hundred ten (110) percent of the total structure height from any property line.
From the ordinance
A temporary meteorological tower shall not exceed one hundred ninety-nine (199) feet in height. No temporary meteorological tower shall be permitted by right on a lot or parcel smaller than five thousand (5,000) acres in size. A temporary meteorological tower shall be setback a distance at least equal to four hundred (400) percent of the total structure height from any property line.