Vienna
Zoning districts
3 districts, grouped by category.
General provisions
322 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.
All lighting fixtures shall be full-cutoff fixtures and shall be mounted such that the cone of light is contained on-site and does not cross any property line.
Maximum luminance levels shall not exceed 0.5 foot-candles at the property boundary.
Parking lot lights shall be a maximum height of 15 feet.
Light fixtures for sidewalks, walkways, trails, and bicycle paths, shall provide at least 1.2 foot-candles of illumination, but not exceed 2.0 foot-candles.
All events shall be scheduled so as to complete all activity before or as near to 10:30 p.m. as practical, but under no circumstances shall any illumination of the playing field, court, or track be permitted after 11:00 p.m.
For purposes of computation under this Chapter, one compact automobile parking space shall be eight (8) feet wide by sixteen (16) feet long.
All parking areas shall be constructed of permanent materials, with an asphalt, concrete, or grid paver surface, meeting the specifications of the Town.
Ingress and egress to a public street shall be provided by means of entrances and exits meeting these same specifications and maintaining a width of not less than twelve (12) feet nor more than twenty-five (25) feet at the street right-of-way line.
All automobile parking areas must be setback five (5) feet from side yard property lines.
All automobile parking areas must be setback five (5) feet from side yard property lines.
All required parking areas shall be located on the site or conveniently nearby, not more than 400 feet in distance from the principal use structure or use.
One (1) loading space per 100,000 square feet of gross floor area.
One (1) loading space per 100,000 square feet of gross floor area.
Short-term: One (1) space per 2,500 square feet but no less than 8 spaces. Long-term: One (1) space per 2,500 square feet.
Short-term: One (1) space per 2,500 square feet but no less than 8 spaces. Long-term: One (1) space per 2,500 square feet.
If dumpsters are used for refuse disposal, then each dumpster shall be located on a concrete pad with minimum dimensions of twenty (20) feet by twelve (12) feet and shall be enclosed by adequate walls or opaque fencing of a minimum of one (1) foot taller than the container, and no taller than eight (8) feet.
each dumpster shall be located on a concrete pad with minimum dimensions of twenty (20) feet by twelve (12) feet and shall be enclosed by adequate walls or opaque fencing of a minimum of one (1) foot taller than the container, and no taller than eight (8) feet.
All rooftop equipment (such as air handling units, exhaust fans, and other mechanical systems and equipment) shall be placed as close to the middle of the roof as possible, to maximize the likelihood that the equipment will not be visible from the right-of-way or from adjacent properties.
All rooftop equipment on any building shall be fully screened from view from the right-of-way and adjacent properties by use of screening material that is consistent with the material found on the building façade.
All utility services including, but not limited to, all wires, cables, pipes, conduits, and appurtenant equipment carrying or used in connection with the furnishing of electric power, telephone, telegraph, cable television, petroleum, gas, steam, water or sewer systems shall, after the effective date of the ordinance from which this section is derived, be placed below the surface of the ground
Source documents