Vienna, Virginia · General provision

Sec. 18-568

Extracted standards

7 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Lighting

  • Full-cutoff fixtures required

    All lighting fixtures shall be full-cutoff fixtures and shall be mounted such that the cone of light is contained on-site and does not cross any property line.

  • Pedestrian bollard lamps shall be mounted no higher than four feet above grade.

  • Maximum illumination at property boundary0.5 fc

    Maximum luminance levels shall not exceed 0.5 foot-candles at the property boundary.

  • Parking lot lights shall be a maximum height of 15 feet.

  • Maximum pedestrian light illumination2 fc

    but not exceed 2.0 foot-candles.

  • Minimum pedestrian light illumination1.2 fc

    Light fixtures for sidewalks, walkways, trails, and bicycle paths, shall provide at least 1.2 foot-candles of illumination

  • Outdoor recreation lighting curfew23 hour

    under no circumstances shall any illumination of the playing field, court, or track be permitted after 11:00 p.m.

From the ordinance

All lighting fixtures shall be full-cutoff fixtures and shall be mounted such that the cone of light is contained on-site and does not cross any property line.
Sec. 18-568