Vienna
Zoning districts
3 districts, grouped by category.
General provisions
322 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.
The standards in this Article 4A apply generally to all new construction, additions, and alterations in any RS-10, RS-12.5, or RS-16 zone. ... Minimum off-street parking required: Two (2) spaces for up to three (3) bedrooms.
The standards in this Article 4B apply generally to all new construction, additions, and alterations in the RMU zone.
The standards in this Article 5A apply to all new construction, additions, and alterations with respect to any commercial, industrial, and mixed uses.
Nonconforming uses may be continued only if not discontinued for more than two (2) years. Nonconforming structures damaged up to 50% may be repaired without variance; if greater than 50%, may be restored to original condition. Repairs must be done within 2 years.
Buffer areas having widths of not less than one hundred (100) feet, landward of the components listed in subsections 1. and 2. of this definition, and adjacent to and landward from each side of any water body with perennial flow.
maintaining minimum clearance of eight (8) feet between the ground and the lowest point of the canopy
expansion or modification of a structure in a resource management area, which results in a disturbance of land exceeding an area of two thousand five hundred (2,500) square feet.
Dedicated parking spaces for electric charging may occupy ten (10) percent of required parking, rounding up to the nearest whole number, and any parking spaces provided above the minimum required.
For single-unit detached dwellings, the finished lot grade may deviate from the pre-existing lot grade by no more than three vertical feet. Building height is measured from average finished lot grade at front to highest point of roof.
For single-unit detached dwellings, finished lot grade may deviate no more than 3 ft. Deck coverage max 5%. Open space min 8 ft wide, 120 sq ft. Roof structures max 9 ft above roof.
Architectural features may be erected beyond the nine (9) foot maximum addition above the roof level... Deck and outdoor living coverage may not exceed 5% of total lot area... Open space must be 8 feet or more in width and 120 sq ft or more in contiguous area.
The purpose of this zone is to provide standards for single-unit, detached residences with a minimum lot area of 12,500 square feet. Principal Structure Count: 1 per lot max.
The purpose of this zone is to provide standards for single-unit, detached residences with a minimum lot area of 12,500 square feet. Principal Structure Count: 1 per lot max.
The purpose of this zone is to provide standards for multi-unit residential uses, which include the following: Two-unit Attached Dwellings/Duplexes, Cottage Courts, Townhomes, Multi-unit Buildings and Complexes.
The purpose of this zone is to provide standards for multi-unit residential uses, which include the following: A. Two-unit Attached Dwellings/Duplexes. B. Cottage Courts. C. Townhomes. D. Multi-unit Buildings and Complexes.
The purpose of the Avenue Center District is to provide standards for the promotion of a strong, vibrant commercial and mixed-use center along Maple Avenue.
The purpose of the Avenue Center District is to provide standards for the promotion of a strong, vibrant commercial and mixed-use center along Maple Avenue.
The purpose of the Avenue East Gateway District is to promote standards for the promotion of a vibrant commercial use area east of the Avenue Center District.
The purpose of the Avenue East Gateway District is to promote standards for the promotion of a vibrant commercial use area east of the Avenue Center District.
The purpose of the Avenue West Gateway District is to provide standards for the promotion of a vibrant commercial use area west of the Avenue Center District.
Source documents
The chapters of the adopted code that were retrieved, read and extracted from. Everything above traces back to one of these.