County (unincorporated) · Virginia

York County Unincorporated

This locality is on the roster but its ordinance has not been retrieved yet.
1
Districts
283
Extracted rules
944
Standards
10
Chapters read
Zoning snapshotNot yet acquired

Zoning districts

1 districts, grouped by category.

General provisions

282 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.

Sec. 24.1-2425 standards

A minimum of thirty-five percent (35%) of all plant material installed on a site shall be of a species native to the Virginia coastal plain. No more than fifty percent (50%) of the required trees shall be of one type (i.e., deciduous, evergreen), nor shall more than twenty-five percent (25%) of the required trees be of a single species. Trees and groups of trees which are to be preserved shall be enclosed by a temporary fence or barrier to be located and maintained five feet (5') outside of their dripline during construction. Where grade changes in excess of six inches (6") from the existing natural grade level are necessary, permanent protective structures such as tree wells or walls shall be indicated on the landscaping plan.

Sec. 24.1-2433 standards

Transitional buffers of the following types shall be provided in the situations identified by the entries in the table contained in section 24.1-243(b)

Sec. 24.1-2436 standards

Where the zoning district boundary line which requires a transitional buffer follows a public street or highway right-of-way of less than ninety feet (90') in width, the following shall apply: ...

Sec. 24.1-2436 standards

Transitional Buffer Type 25: Shall consist of a strip of open space, a minimum of twenty-five feet (25') wide, landscaped with evergreen trees and shrubs to achieve a minimum of 0.75 landscape credits for every linear foot measured along the outside edge of the transitional buffer. Transitional Buffer Type 35: ... a minimum of thirty-five feet (35') wide ... 1 landscape credit per linear foot. Transitional Buffer Type 50: ... a minimum of fifty feet (50') wide ... 1.25 landscape credits per linear foot.

Sec. 24.1-243 (Transitional buffers)5 standards

Aboveground or underground utilities shall not be located within transitional buffers except those which cross the buffer at a right angle.

Sec. 24.1-2444 standards

The minimum dimensions of landscape yards around the site perimeter shall be twenty feet (20') for front yards and ten feet (10') for side and rear yards, to be measured from the lot line...

Sec. 24.1-2444 standards

The minimum dimensions of landscape yards around the site perimeter shall be twenty feet (20') for front yards and ten feet (10') for side and rear yards

Sec. 24.1-2451 standards

Along the Colonial Parkway, a greenbelt of no less than three hundred feet (300') from the nearest edge of the roadway shall be provided.

Sec. 24.1-2454 standards

Greenbelts shall be provided contiguous to the street right-of-way along the following roads in accordance with the specified minimum widths

Sec. 24.1-2512 standards

Any residential, commercial, industrial use, or combination thereof, where the anticipated average weekday twenty-four (24) hour traffic generation... equals or exceeds one thousand (1,000) trip ends or where the traffic volume during a peak hour equals or exceeds one hundred (100) trip ends...

Sec. 24.1-251 to 24.1-25613 standards

Any residential, commercial, industrial use... where the anticipated average weekday twenty-four (24) hour traffic generation... equals or exceeds one thousand (1,000) trip ends or where the traffic volume during a peak hour equals or exceeds one hundred (100) trip ends

Sec. 24.1-2524 standards

Access to a use shall be considered to be part of the use and shall require an equivalent or greater intensity zoning classification, unless over a publicly owned and maintained right-of-way.

Sec. 24.1-2564 standards

Driveways shall be spaced at least fifty feet (50') apart. Where such spacing requirements cannot be readily achieved, joint access with an adjoining parcel shall be encouraged.

Sec. 24.1-2604 standards

New construction on existing slopes in excess of thirty percent (30%) shall be prohibited unless the zoning administrator... determines that such construction can be accommodated without creating or exacerbating erosion, seepage, or nutrient transport problems.

Sec. 24.1-2604 standards

New construction on existing slopes in excess of thirty percent (30%) shall be prohibited unless the zoning administrator... determines that such construction can be accommodated

Sec. 24.1-2615 standards

Dumpsters shall not be located closer than fifty feet (50') to any residential structure nor closer than twenty feet (20') to any non-residential structure.

Sec. 24.1-2616 standards

Dumpsters shall not be located closer than fifty feet (50') to any residential structure nor closer than twenty feet (20') to any non-residential structure.

Sec. 24.1-2622 standards

All on-site utility facilities including but not limited to wires, cables, pipes, conduits and appurtenant equipment... shall be placed underground except, however, the following shall be permitted above ground: ...

Sec. 24.1-2622 standards

All on-site utility facilities... shall be placed underground except... Electric transmission lines and facilities in excess of fifty (50) kilovolts

Sec. 24.1-270

Unless otherwise provided herein, accessory uses and structures shall be permitted in any zoning district, but only in connection with, incidental to, and on the same lot with a principal use or structure which is lawfully permitted within such district.

Source documents

The chapters of the adopted code that were retrieved, read and extracted from. Everything above traces back to one of these.