County (unincorporated) · Virginia

York County Unincorporated

This locality is on the roster but its ordinance has not been retrieved yet.
1
Districts
283
Extracted rules
944
Standards
10
Chapters read
Zoning snapshotNot yet acquired

Zoning districts

1 districts, grouped by category.

General provisions

282 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.

Sec. 24.1-2231 standards

the normally required front yard and front perimeter landscape yard depths for said development shall be increased by an amount which is equal to one-half (½) of the total right-of-way deficiency.

Sec. 24.1-223.11 standards

the 20-foot front landscaped yard required by section 24.1-244 may be reduced to five feet

Sec. 24.1-223.11 standards

if the front property line of said parcel is 50 feet or more from the edge of the existing pavement the 20-foot front landscaped yard required by section 24.1-244 may be reduced to five feet

Sec. 24.1-2241 standards

such structures shall be located at least twenty feet (20') from one another.

Sec. 24.1-2241 standards

In the case of development proposals where two (2) or more principal structures are permitted to be located on a single lot, such structures shall be located at least twenty feet (20') from one another.

Sec. 24.1-2256 standards

Awnings and bay windows which are not more than ten feet (10') wide may extend three feet (3') into a required yard.

Sec. 24.1-2253 standards

Awnings and bay windows which are not more than ten feet (10') wide may extend three feet (3') into a required yard. The ordinary projections of eaves, gutters, chimneys, and flues may extend into a required yard not to exceed three feet (3'). Uncovered stoops and uncovered landings shall not exceed six feet (6') by six feet (6') into a required yard.

Sec. 24.1-2261 standards

Signs, plantings, structures or other obstructions which obscure or impede sight lines between three feet (3') and six feet (6') in height above grade shall be prohibited within the sight triangle.

Sec. 24.1-2261 standards

Signs, plantings, structures or other obstructions which obscure or impede sight lines between three feet (3') and six feet (6') in height above grade shall be prohibited within the sight triangle.

Sec. 24.1-2301 standards

The general height regulations of the district in which a parcel is located shall apply to all principal and accessory structures

Sec. 24.1-2313 standards

Church spires, belfries, cupolas, monuments, chimneys, water towers, fire towers, cooling towers, electric substation components, radio and television antennas may be permitted to exceed the height stipulated in the district regulations by no more than twenty-five percent (25%)

Sec. 24.1-2313 standards

Church spires, belfries, cupolas, monuments, chimneys, water towers, fire towers, cooling towers, electric substation components, radio and television antennas may be permitted to exceed the height stipulated in the district regulations by no more than twenty-five percent (25%) if attached to a building, or to a maximum of one hundred feet (100') if free-standing. Parapet walls or similar structures may exceed the maximum height limit by not more than eight feet (8').

Sec. 24.1-2322 standards

Buildings in excess of fifty feet (50') in height, such height for the purposes of this subsection being measured to the highest part of the roof, shall have accessible fire lanes surrounding the entire building

Sec. 24.1-2321 standards

Any two (2) buildings in excess of fifty feet (50') in height, such height for the purposes of this subsection being measured to the highest part of the roof, shall be separated from each other by no less than forty feet (40').

Sec. 24.1-2332 standards

Any single-family detached dwelling having a ridgeline or highest part of the roof in excess of thirty-five feet (35') above average finished grade shall be designed and constructed to meet the following standards

Sec. 24.1-2332 standards

Any single-family detached dwelling having a ridgeline or highest part of the roof in excess of thirty-five feet (35') above average finished grade shall be designed and constructed to meet the following standards: ... Exterior access to both the roof and the uppermost occupied story shall be no higher than thirty feet (30') above finished grade at any point. ... No such structure or portion thereof shall be further than six hundred feet (600') from a fire hydrant.

Sec. 24.1-233.12 standards

The allowable building height for single-family detached residential structures located in a Special Flood Hazard Area ... may be increased by one foot (1') for each foot the structure is elevated above the base flood level, not to exceed however a building height of forty-five feet (45')

Sec. 24.1-233.13 standards

The allowable building height for single-family detached residential structures located in a Special Flood Hazard Area ... may be increased by one foot (1') for each foot the structure is elevated above the base flood level, not to exceed however a building height of forty-five feet (45'), subject to the following standards and requirements: (a) The minimum required front, side and rear building setback of structures constructed pursuant to this section shall be increased by one foot (1') for every one foot (1') of building height in excess of thirty-five feet (35').

Sec. 24.1-2412 standards

A landscape plan shall be required in conjunction with any development project requiring site plan or development plan approval

Sec. 24.1-2424 standards

A minimum of thirty-five (35%) of all plant material installed on a site shall be of a species native to the Virginia coastal plain

Source documents

The chapters of the adopted code that were retrieved, read and extracted from. Everything above traces back to one of these.