County (unincorporated) · Virginia

Loudoun County Unincorporated

This locality is on the roster but its ordinance has not been retrieved yet.
22
Districts
931
Extracted rules
2,878
Standards
14
Chapters read
Zoning snapshotNot yet acquired

Zoning districts

22 districts, grouped by category.

Residential

15
R-1Residential

Single-Family Residential R-1 Legacy Zoning District

Loudoun County Unincorporated, VA
Min lot
40,000 sq ft (0.92 ac)
Permitted uses
1
R-16Residential

R-16 Townhouse/Multifamily Legacy Zoning District

Loudoun County Unincorporated, VA
Max height
40 ft
Front setback
25 ft
Max density
16 du/ac
Permitted uses
3
R-2Residential

Single-Family Residential R-2 Legacy Zoning District

Loudoun County Unincorporated, VA
Min lot
20,000 sq ft (0.46 ac)
Permitted uses
2
R-24Residential

Multifamily Residential R-24 Legacy Zoning District

Loudoun County Unincorporated, VA
Max height
45 ft
Front setback
25 ft
Max density
24 du/ac
Permitted uses
1
R-3Residential

Single-Family Residential R-3 Legacy Zoning District

Loudoun County Unincorporated, VA
Min lot
15,000 sq ft (0.34 ac)
Permitted uses
2
R-4Residential

Single Family Residential R-4 Legacy Zoning District

Loudoun County Unincorporated, VA
Min lot
10,000 sq ft
Max height
40 ft
Front setback
25 ft
Max density
4 du/ac
Permitted uses
2
R-8Residential

Single Family Residential R-8 Legacy Zoning District

Loudoun County Unincorporated, VA
Max height
40 ft
Front setback
15 ft
Max density
8 du/ac
Permitted uses
6
SCN-16Residential

Suburban Compact Neighborhood - 16

Loudoun County Unincorporated, VA
Max height
50 ft
Permitted uses
40
SCN-24Residential

Suburban Compact Neighborhood - 24

Loudoun County Unincorporated, VA
Max height
50 ft
Permitted uses
41
SCN-8Residential

Suburban Compact Neighborhood - 8

Loudoun County Unincorporated, VA
Max height
50 ft
Front setback
15 ft
Permitted uses
47
SN-4Residential

Suburban Neighborhood - 4

Loudoun County Unincorporated, VA
Max height
50 ft
Front setback
15 ft
Permitted uses
51
SN-6Residential

Suburban Neighborhood - 6

Loudoun County Unincorporated, VA
Max height
50 ft
Permitted uses
49
TR-1Residential

Transitional Residential-1

Loudoun County Unincorporated, VA
Max height
40 ft
TR-2Residential

Transitional Residential-2

Loudoun County Unincorporated, VA
Max height
35 ft
Front setback
10 ft
TR-3Residential

Transitional Residential-3

Loudoun County Unincorporated, VA

General provisions

909 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.

Section 7.04.034 standards

Buffer Types A, B, and C are described: Aesthetic, Semi-opaque, Opaque. Buffer Type C requires a 6-foot-high fence, wall, or berm with 95% opacity.

Section 7.04.03.A.73 standards

Specific Uses under Chapter 4 that reference Section 7.04 must provide between the Specific Use and any existing adjacent lot 4 acres or less or containing a dwelling within 300 feet: minimum 50-foot setback, Road Corridor Buffer Type 2 for front yards, and a 6-foot-high fence/wall/berm with 95% opacity for sides and rear.

Section 7.04.042 standards

For a cemetery, burial ground, or grave on the developing property, a 25-foot protection buffer must be established outside of and abutting the delineated perimeter boundary; a 25-foot preservation buffer must be established outside of and abutting the protection buffer.

Section 7.04.044 standards

Cemetery, Burial Ground, and Grave Buffer comprises perimeter boundary, protection buffer, and preservation buffer. Protection buffer 25 ft, preservation buffer 25 ft. Perimeter fence 3-4 ft high. No land disturbing activity except certain exceptions.

Section 7.04.053 standards

On-site components must be screened from view at the ground level from all public roads and adjoining parcels using at least one of the following: an opaque fence or wall that is a minimum of 6 feet in height; a berm that is a minimum of 3 feet in height with evergreen plantings that are a minimum of 6 feet in height at time of planting.

Section 7.04.054 standards

On-site components must be screened from view from public roads and adjoining parcels using at least one: opaque fence/wall min 6 ft, berm min 3 ft with evergreen plantings min 6 ft, or architectural element. Parapet max height equal to top of highest mechanical unit but not exceed max height by more than 3 ft.

Section 7.04.0611 standards

At least 5% of the gross area of the parking area must be interior parking area landscaping. ...

Section 7.04.066 standards

Any property with 20 or more parking spaces must include interior parking area landscaping: at least 5% of gross area, min 130 sq ft per area, 10 plant units per 150 sq ft, no parking space more than 80 ft from a large deciduous tree. Peripheral parking area landscaping: min height 30 inches, 50 plant units per 100 linear feet in 10-ft strip.

Section 7.04.06.A1 standards

Any property, use, or parking area that contains 20 or more parking spaces, except areas used for accessory storage of vehicles, must include interior parking area landscaping.

Section 7.04.079 standards

The plant types used to meet the Plant Unit requirements for each Buffer or Road Corridor Buffer must meet the following: ...

Section 7.04.072 standards

At the time of planting, all trees and shrubs must meet the requirements of the American National Standards Institute, American Standard for Nursery Stock, ANSI Z60.1-2014.

Section 7.04.07.B10 standards

Plant units must meet composition requirements: no more than 50% large deciduous, no more than 50% evergreen, min 10% evergreen for Type C, no more than 60% small deciduous, no more than 30% shrubs, min 30% evergreen shrubs, max 25% ornamental grasses, min 80% native, min 75% pollinator, no invasive.

Section 7.04.08

The Zoning Administrator may adjust or waive Road Corridor Buffer and Buffer Type requirements of Section 7.04 as part of the Site Plan, Subdivision, and/or Zoning Permit process...

Section 7.05.028 standards

Lighting fixtures must be full cutoff... Maximum illumination 0.25 foot-candles above background light levels measured at the lot line...

Section 7.05.029 standards

Lighting fixtures must be full cutoff so that the emitted light is not projected above the horizontal plane of the shield, or bulb enclosure, and the bulb is recessed or level with the lowest portion of the lighting shield.

Section 7.05.033 standards

No loading/unloading activities or other noise-producing activities are permitted within 250 feet of an existing principal dwelling.

Section 7.05.033 standards

No loading/unloading activities or other noise-producing activities are permitted within 250 feet of an existing principal dwelling.

Section 7.05.043 standards

Between the hours of 8:00 p.m. and 7:00 a.m., all of the permissible vibration levels ... must be reduced to one-half the indicated values.

Section 7.05.041 standards

Between the hours of 8:00 p.m. and 7:00 a.m., all of the permissible vibration levels indicated in Table 7.05.04-1 and Table 7.05.04-2 above at residential district boundaries must be reduced to one-half the indicated values.

Section 7.06.015 standards

When the calculation of the number of required parking and loading spaces results in a fractional space: a minimum of 1 parking or loading space must be provided; fractions less than or equal to 0.50 are to be discarded...

Source documents

The chapters of the adopted code that were retrieved, read and extracted from. Everything above traces back to one of these.