Dimensional standards
Extracted standards
9 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Site plan required for additions to existing multifamilyMultifamily dwellingA building of four or more dwelling units. Where zoning is most restrictive./commercial/industrial buildings
Additions to existing multiple-family, commercial, or industrial buildings, except that additions of less than ten (10) percent of the total square footage are permitted without a site plan unless such additions result in the need for ten (10) or more additional parking spaces
- Site plan required for commercial and industrial buildings and uses
Commercial and industrial buildings and uses
- Site plan required for religious, schools, child-care, hospitals, nursing homes, government offices
Religious assembly and institutions, public and private schools, child-care centers, hospitals, nursing homes and government offices
- Site plan required for land disturbance >=10,000 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000. or >=2,500 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000. in Chesapeake Bay Preservation Area10,000 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
Any development where the area of land disturbance will be ten thousand (10,000) square feet or greater, or two thousand five hundred (2,500) square feet or greater in a Chesapeake Bay Preservation Area
- Site plan required for multiple-family dwelling developments
Multiple-family dwelling developments
- Site plan required for parking lots with >10 spaces10 spaces
Any parking lot or parking facility which is to contain more than ten spaces
- Site plan required for public improvements
Any development that involves the provision of public improvements, such as streets, curbs, water, sewer and stormwater facilities
- Site plan required for planned unit developments
Planned unit developments
- Site plan required for special use permitConditional useAllowed only after a discretionary approval — usually a public hearing and a board vote. uses
Uses permitted by approval of a special use permit
From the ordinance
Site plans for the following developments and uses shall be submitted and reviewed: Planned unit developments; Uses permitted by approval of a special use permit; Commercial and industrial buildings and uses; Religious assembly and institutions, public and private schools, child-care centers, hospitals, nursing homes and government offices; Multiple-family dwelling developments; Any development where the area of land disturbance will be ten thousand (10,000) square feet or greater, or two thousand five hundred (2,500) square feet or greater in a Chesapeake Bay Preservation Area; Any development that involves the provision of public improvements; Any parking lot or parking facility which is to contain more than ten spaces; Additions to existing multiple-family, commercial, or industrial buildings, except that additions of less than ten (10) percent of the total square footage are permitted without a site plan unless such additions result in the need for ten (10) or more additional parking spaces.