Kilmarnock, Virginia · General provision

Sec. 54-502(a)(3)

Dimensional standards

Servicing

Geographic extent
Areas shown on the Flood Insurance Rate Map (FIRM) as A special flood hazard area.

Extracted standards

9 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Floodplain

  • Anchoring required

    New construction and substantial improvements shall be according to section 54-502 of this article and the VA USBC, and anchored to prevent flotation, collapse or lateral movement of the structure.

  • Enclosure opening requirements

    Provide a minimum of two openings on different sides... total net area of all openings must be at least one square inch for each square foot of enclosed area... bottom of all required openings shall be no higher than one foot above the adjacent grade.

  • Flood-resistant materials

    New construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage.

  • Floodproofing elevation1 ft

    all areas of the building components below the elevation corresponding to the BFE plus one foot are watertight

  • Minimum elevation above base flood elevation1.5 ft

    lowest floor, including basement, elevated at least one and one-half feet above the base flood level.

  • Utility flood protection

    Electrical, heating, ventilation, plumbing, air conditioning equipment and other service facilities, including duct work, shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding.

  • Water and sewage flood protection

    New and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system. New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and discharges from the systems into floodwaters.

Other

From the ordinance

The A zone on the FIRM accompanying the FIS shall be those areas for which no detailed flood profiles or elevations are provided, but the one-percent annual chance floodplain boundary has been approximated. When such base flood elevation data is utilized, the lowest floor shall be elevated at least one and one-half feet above the base flood level.
Sec. 54-502(a)(3)