Dimensional standards
Servicing
- Geographic extent
- Areas shown on the Flood Insurance Rate Map (FIRM) as AE or AH special flood hazard area.
Extracted standards
9 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Floodplain
- Anchoring required
New construction and substantial improvements shall be according to section 54-502 of this article and the VA USBC, and anchored to prevent flotation, collapse or lateral movement of the structure.
- Enclosure opening requirements
Provide a minimum of two openings on different sides... total net area of all openings must be at least one square inch for each square foot of enclosed area... bottom of all required openings shall be no higher than one foot above the adjacent grade.
- Flood-resistant materials
New construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage.
- Floodproofing elevation1 ft
all areas of the building components below the elevation corresponding to the BFE plus one foot are watertight
- Minimum elevation above base flood elevation1.5 ft
lowest floor, including basement, elevated at least one and one-half feet above the base flood level.
- Utility flood protection
Electrical, heating, ventilation, plumbing, air conditioning equipment and other service facilities, including duct work, shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding.
- Water and sewage flood protection
New and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system. New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and discharges from the systems into floodwaters.
Other
- Base flood elevation data required
Base flood elevation data shall be obtained from other sources or developed using detailed methodologies... for subdivision proposals and other proposed development proposals (including manufactured home parks and subdivisions) that exceed 50 lots or five acres, whichever is the lesser.
- Maximum accessoryAccessory useA secondary activity customarily incidental to the main use of the lot — a garage, a home office. structure size200 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
Accessory structures not to exceed 200 sq. ft.
From the ordinance
The AE, or AH zones on the FIRM accompanying the FIS shall be those areas for which one-percent annual chance flood elevations have been provided and the floodway has not been delineated. Until a regulatory floodway is designated, no new construction, substantial improvements, or other development (including fill) shall be permitted within the areas of special flood hazard, designated as zones A1-30 and AE or AH on the FIRM, unless it is demonstrated that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, will not increase the water surface elevation of the base flood more than one foot at any point within the Town of Kilmarnock.