Extracted standards
11 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Design
- Access from interior of site
Access to all self-service storage rental spaces must be from the interior of the site. No individual storage bay doors, storage items, or lighted hallways along the lengths of the building façades may be visible from the public right-of-way.
- Maximum caretaker quarters1 count
No more than one security or caretaker quarters may be developed on the site
- Storage within enclosed buildings
all personal property shall be stored within enclosed buildings.
Other
- Fire hydrants required
Fire hydrants and/or fire suppression devices shall be provided, installed, and maintained in compliance with applicable codes and regulations.
- Loading/unloading screened
Loading and unloading areas must be located, screened or fully enclosed to minimize the potential for adverse impacts on adjacent property.
- Paved access ways
All access ways on the site shall be paved with asphalt, concrete, or comparable paving materials.
- ProhibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. hazardous materials
No storage of hazardous, toxic, or explosive materials shall occur in the facility.
- ProhibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. incidental parking of motor vehicles
Incidental parking or storage of motor vehicles, including trucks or moving vans is not allowed, except for purposes of loading and unloading, or if approved as a part of a automobile sales and rental establishment.
- ProhibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. manufacturing, repair, sales
No portion of the facility shall be used to manufacture, fabricate, or process goods; to service or repair vehicles, small engines, or electrical equipment, or conduct similar repair activities; to conduct sales or retail sales of any kind, or to conduct any other commercial or industrial activity on the site.
- ProhibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. portable storage containers
Self-storage facilities shall not include portable storage containers, shipping containers and/or tractor trailers.
All areas with street frontage not occupied by a building or structure shall include a wall/fence or screening in accordance with article VIII, community design standards, of this ordinance.
From the ordinance
No portion of the facility shall be used to manufacture, fabricate, or process goods; to service or repair vehicles, small engines, or electrical equipment, or conduct similar repair activities; to conduct sales or retail sales of any kind, or to conduct any other commercial or industrial activity on the site.