Sec. 607.05, 607.06, 607.07
Dimensional standards
Lot
Uses
Permitted by right35
- accessory uses
- automotive repair services, major
- amusement enterprises
- art or photography studios
- automobile service stations
- blacksmith shop, welding, or machine shop
- bottling plants or distribution operations
- building and contractor's storage and equipment yards
- bus terminal facilities
- car washes
- childcare centers
- clinics and doctors' offices
- commercial communications equipment
- funeral homes
- government facilities
- hydroponic agriculture
- indoor sport facilities
- libraries
- lumber and/or building materials sales
- manufacturing, custom
- manufacturing, light
- motor vehicle sales
- museums, art galleries, civic or cultural centers, historic exhibits
- offices
- parking facilities, public or private
- pharmaceuticals, diagnostic testing and other laboratories
- plant nurseries
- printing, bookbinding, and publishing
- public parks
- rehabilitation facilities
- religious assembly
- veterinary hospital or animal shelter for small animals
- warehousing, mini-storage, or warehouse units totaling less than 15,000 square feet floor gross floor area
- winery, brewery, or distillery
- utilities, public
Conditional / special use10
- commercial retail
- commercial services
- data processing facilities
- eating establishments
- eating establishment, with drive through
- lodges
- private parks, playgrounds and other outdoor recreation, and open space areas
- satellite dishes
- schools
- utilities, private
Extracted standards
12 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Lighting
- Maximum illumination at lot line0.1 footcandles
Light emitted for any operation or activity shall not exceed an illumination level of 0.1 footcandles at any lot line adjoining a residential district
- Maximum illumination at lot line1 footcandles
nor 1.0 footcandles at any lot line adjoining a commercial or industrial district
- Maximum light source brightness150 footlamberts
no light source with an intrinsic brightness level of 150 footlamberts or greater shall be located within 500 feet of any residential district
Noise
- Maximum noise level65 dBA-L2
The noise generated by the use shall not exceed a level of 65 dBA-L2 at any lot line adjoining a residential district
- Maximum noise level75 dBA-L10
nor a level of 75 dBA-L10 at any lot adjoining commercial or industrial districts.
Other
- Brick required on facades visible from public right-of-way
Brick shall be required on all sides of units that will be visible from the public right-of-way of streets.
- All operations within enclosed building
All business, servicing, storage, or processing shall be conducted within a completely enclosed building except where the nature of the activity makes it impossible.
- Front setbackSetbackThe distance a building must be held back from a lot line. landscaping required
The front setback shall be 25 feet with required landscaping
- Maximum vibration at lot line0.1 inches per second
shall not exceed 0.1 inches per second at the lot line of the proposed use
- Maximum vibration in commercial districtZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2.0.05 inches per second
0.05 inches per second in any commercial district
- Maximum vibration in residential districtZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2.0.02 inches per second
and 0.02 inches per second in any residential district.
- Minimum distance from residential districtZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2. for building openings100 ft
All operations shall be conducted within a building which shall not have an opening within 100 feet of a residential district other than a stationary window
From the ordinance
The minimum lot area shall be 25,000 square feet. The maximum height of any building shall be 50 feet.