Riverside County Unincorporated, California · General provision
17.123.020(3)
Single FamilyAll Riverside County Unincorporated districts0
Dimensional standards
Extracted standards
2 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Maximum architectural encroachment into setbacksSetbackThe distance a building must be held back from a lot line.2 ft
Fireplaces, media niches, bay windows, porches, window boxes, and similar architectural elements shall be allowed to encroach a maximum of two feet into setbacks provided at least one side of the structure has a five foot setback.
- Pool, spa, and associated equipment setbackSetbackThe distance a building must be held back from a lot line.5 ft
The edge of any pool, spa and associated equipment shall be at least five feet from any property line.
From the ordinance
Building height shall not exceed two stories, with a maximum height of twenty-six (26) feet... The minimum lot area shall be three thousand eight hundred (3,800) square feet... The minimum frontage of a lot shall be thirty-five (35) feet.