Industrial
2General provisions
225 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.
Any use not listed in this table is not permitted in multiple purpose districts.
Any use not listed in this table is not permitted in multiple purpose districts.
Municipal or county buildings | P | P | P | P |; Parks | P | P | P | P |
Dwelling, single-family | P | | | | | |
Hotels and motels | | P | P | | | |
Hotels and motels | | P | P | | | |
Municipal or county buildings | P | P | P | P | | |
Drive-up facilities shall provide a minimum number of stacking spaces on site in accordance with the standards below... Each stacking space shall be a minimum of 20 feet in length and ten feet in width...
Speakers shall be located at least 50 feet from the property line of any residentially zoned property.
No deck, patio, terrace or other outside area for the service or accommodation of patrons shall be situated within 100 feet of any property in any residential or R-B district; Covered trash containers shall be provided...
No deck, patio, terrace or other outside area for the service or accommodation of patrons shall be situated within 100 feet of any property in any residential or R-B district
On a lot developed with a single-family dwelling or two-family dwelling, the height of a flagpole is limited to 30 feet. On a lot developed with a principal use other than a single-family dwelling or two-family dwelling, the height of a flagpole is limited to 60 feet.
On a lot developed with a single-family dwelling or two-family dwelling, the height of a flagpole is limited to 30 feet. On a lot developed with a principal use other than a single-family dwelling or two-family dwelling, the height of a flagpole is limited to 60 feet.
The maximum number of adult guests in a homestay unit is limited to six and no more than five sleeping rooms can be utilized during any one stay.
The maximum number of adult guests in a homestay unit is limited to six and no more than five sleeping rooms can utilized during any one stay.
Minimum site size: Five contiguous acres. Maximum density: Six units per gross acre. Minimum area of manufactured home space: 5,000 square feet. ... Every manufactured home park shall be served by public sewer and public water systems.
Minimum site size: Five contiguous acres. Maximum density: Six units per gross acre. Minimum area of manufactured home space: 5,000 square feet.
Dwelling units shall be located above the first floor of the building or to the rear of other permitted uses.
Lots containing a mixed-use building shall not have more than two dwelling units.
Dwelling units shall be located above the first floor of the building or to the rear of other permitted uses. ... The minimum gross floor area of the building shall be not less than 10,000 square feet.