Dimensional standards
Extracted standards
11 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Buffer width25 ft
A landscaped buffer area of not less than 25 feet in width shall be provided adjacent to all boundaries of a manufactured home park.
- Front yardYardThe open space left between a building and its lot line — the space a setback creates. from interior roadway20 ft
No manufactured home, accessory structure or other building or structure within a manufactured home park shall be located within 20 feet of an interior roadway or within 25 feet of any public street right-of-way.
- Front yardYardThe open space left between a building and its lot line — the space a setback creates. from public street25 ft
No manufactured home, accessory structure or other building or structure within a manufactured home park shall be located within 20 feet of an interior roadway or within 25 feet of any public street right-of-way.
- Minimum site size5 acresacre43,560 square feet — about the size of an American football field without the end zones.
Minimum site size: Five contiguous acres.
- Minimum manufactured homeManufactured homeA dwelling built in a factory to a federal standard and transported to the site. space area5,000 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
Minimum area of manufactured home space: 5,000 square feet.
- Minimum manufactured homeManufactured homeA dwelling built in a factory to a federal standard and transported to the site. space length100 ft
Minimum dimensions of manufactured home space: 50 feet in width and 100 feet in length.
- Minimum manufactured homeManufactured homeA dwelling built in a factory to a federal standard and transported to the site. space width50 ft
Minimum dimensions of manufactured home space: 50 feet in width and 100 feet in length.
- Minimum street frontageFrontageThe length of a lot line that touches a public street.200 ft
Every manufactured home park shall have not less than 200 feet of frontage on an improved public street.
- Recreation area percentage10 pct
Such areas shall in the aggregate consist of not less than ten percent of the gross area of the manufactured home park.
- Separation between manufactured homesManufactured homeA dwelling built in a factory to a federal standard and transported to the site.30 ft
No manufactured home shall be located within 30 feet of any other manufactured home.
- YardYardThe open space left between a building and its lot line — the space a setback creates. from park boundary10 ft
No manufactured home or other building or structure shall be located within ten feet of a boundary of a manufactured home space.
From the ordinance
Minimum site size: Five contiguous acres. Maximum density: Six units per gross acre. Minimum area of manufactured home space: 5,000 square feet. ... Every manufactured home park shall be served by public sewer and public water systems.