Municipality · Virginia

Haymarket

This locality is on the roster but its ordinance has not been retrieved yet.
6
Districts
186
Extracted rules
496
Standards
22
Chapters read
Zoning snapshotNot yet acquired

Zoning districts

6 districts, grouped by category.

General provisions

180 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.

Sec. 58-3.7(37)1 standards

If development is to occur near North Fork Creek, a 100-foot-wide buffer area of undisturbed vegetation is required.

Sec. 58-3.7(38)1 standards

A plat notation regarding on-site septic systems to be pumped out every five years.

Sec. 58-3.7(39)1 standards

Notation regarding requirement for 100 percent reserve drain field sites for on-site sewage treatment systems.

Sec. 58-3.7(40)1 standards

Development in the RPA is limited to water dependent facilities or redevelopment, including the 100-foot-wide vegetated buffer.

Sec. 58-3.7(b)(31)-(35)3 standards

A plat notation to retain an undisturbed and vegetated 100-foot-wide buffer area located along other water bodies with perennial flow. If development is to occur near North Fork Creek, a 100-foot-wide buffer area of undisturbed vegetation is required. Development in the RPA is limited to water dependent facilities or redevelopment, including the 100-foot-wide vegetated buffer.

Sec. 58-3.7(b)(33)-(34)2 standards

A plat notation regarding on-site septic systems to be pumped out every five years. Notation regarding requirement for 100 percent reserve drain field sites for on-site sewage treatment systems.

Sec. 58-4.11 (as referenced)3 standards

A phase I cultural resources survey, performed in accordance with the guidelines of the Virginia Department of Historic Resources... Traffic impact analysis... If proposed, provisions for affordable housing units for any development on which a residential component is to be constructed.

Sec. 58-4.126 standards

The contour interval shall not be more than five feet.

Sec. 58-4.122 standards

The contour interval shall not be more than five feet. The contours shall be shaded in a graphic technique showing slope conditions of 15 to 25 percent and another distinguishing graphic technique showing greater than 25 percent slope.

Sec. 58-4.12(4) and Sec. 58-4.13(a)2 standards

All written statements and all plans... shall be presented on a sheet or sheets having a size of no larger than 24 by 36 inches. The master zoning plan (MZP) shall be prepared using a convenient scale so that the entire parcel can be shown on a single sheet of paper no larger than 30 inches by 42 inches.

Sec. 58-4.132 standards

The master zoning plan (MZP) shall be prepared using a convenient scale so that the entire parcel can be shown on a single sheet of paper no larger than 30 inches by 42 inches.

Sec. 58-4.177 standards

Changes in a building's minimum floor area ratio (FAR) specified in an adopted proffered condition, so long as the building's gross floor area is increased or reduced by no more than 0.1 FAR

Sec. 58-4.17(f) and Sec. 58-4.31(1)3 standards

An increase in the maximum number of children approved for a child-care facility, so long as the approved number does not exceed (1) five percent of the maximum number of children listed in the adopted proffered conditions; or (2) additional children, whichever is greater. Changes in a building's minimum floor area ratio (FAR) specified in an adopted proffered condition, so long as the building's gross floor area is increased or reduced by no more than 0.1 FAR. Changes in a building's minimum or maximum height specified in an adopted proffered condition, so long as the building's height is increased or reduced by no more than ten feet.

Sec. 58-4.302 standards

After approval of a special use permit by the Haymarket Town Council, the applicant shall have one year to submit site or subdivision plans for the approved use and shall occupy the site and commence the use within five years of approval of the site plan

Sec. 58-4.410 standards

Notice of a map amendment or special use permit shall be given by the posting of at least one sign on the property involved at least 15 days prior to the date of the public hearing.

Sec. 58-4.51 standards

written notice of such changes to zoning ordinance text regulations shall not have to be mailed to the owner, owners, or their agent of lots shown on a subdivision plat approved and recorded pursuant to the provisions of Code of Virginia, §§ 15.2-2240 et seq., where such lots are less than 11,500 square feet.

Sec. 58-7.13 standards

At the time of erection of any main building, or at the time any main building or its accessory uses is enlarged, or the use changed, all provisions of article XIII shall be met along with minimum required off-street parking and loading space with adequate provision for entrance and exit of motor vehicles, in accordance with the following table.

Sec. 58-7.23 standards

It is a violation of the Haymarket Zoning Ordinance to store, on any property zoned or used for residential purposes, any motor vehicle or trailer which is inoperable or inoperative, unless such motor vehicle or trailer is stored within a fully enclosed building or structure, or otherwise fully shielded or screened for view.

Subdivision Ordinance, Section 600-11731 standards

The division of land for the purpose of creating a lot for a public [various-use] center facility;

Unspecified

The division of land for the purpose of creating a lot for a public health center;

Source documents

The chapters of the adopted code that were retrieved, read and extracted from. Everything above traces back to one of these.