Ventura, California · District

T5.2

Urban Center Zone (T5.2)

Dimensional standards

T5.2 lot requirementsSTREETSTREETbuildable areaFront 0 ftRear 5 ftSide 0 ftStreet side 0 ftMin frontage 5 ftMAX HEIGHT75 ft / 6 stories
Plan view of the district’s stated lot requirements. Solid line: the property line. Dashed: the setback lines the ordinance imposes; a building must stay inside the tinted envelope. Drawn from the figures extracted below — illustrative, not a survey.

Uses

Extracted standards

7 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

From the ordinance

Front setback: zero feet minimum, 10 feet maximum. Maximum height: six stories. Accessory buildings: 24 feet maximum to eave. Allowed frontage types: stoop, forecourt, shopfront and awning, gallery, arcade. Buildings two stories high shall be set back a minimum of 20 feet from any single-family residential lot.
24.595.120

Parking requirements

{
  "condominiums": "two and one-half spaces per unit (two in garage)",
  "nonresidential": "one space per 300 sq ft gross floor area",
  "one_to_two_dwelling_units": "two-car garage per unit",
  "three_dwelling_units_apartments": "one covered for one bedroom units; one covered plus one uncovered for two-plus bedroom units; one-quarter uncovered/unit for guest parking"
}