R-1-B
Dimensional standards
Lot
Height & bulk
Slope & grading
- Slope regulation triggers at
- 10%
Uses
Permitted by right7
Conditional / special use8
Prohibited2
Extracted standards
23 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Density
- Maximum kitchens per dwelling unitDwelling unitOne independent home: its own kitchen, bathroom and entrance.1 unit
No more than one kitchen shall be allowed per dwelling unit.
Height
- Stepback above 22 feet10 ft
Any portion of a building or other structure over 22 feet in height shall be set back at least an additional 10 feet beyond the required front setback line.
Other
Body work on a vehicle is prohibited.
- Design review required
Design review approval must be obtained to the extent required by Chapter 24.545.
- Factory-built homes allowed
Factory-built homes may be used for residential purposes in the same manner as conventional site-built housing.
- Group care
Group Care uses must comply with the provisions of Chapter 24.435.
Home occupations may be conducted in the R-1-B zone only to the extent permitted by Chapter 24.125.
- Livestock animals prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
Livestock animals are not permitted in the R-1-B zone.
- Maximum dogs per dwelling unitDwelling unitOne independent home: its own kitchen, bathroom and entrance.3 dogs
No more than three adult dogs shall be permitted per dwelling unit.
- Maximum domestic animals per dwelling unitDwelling unitOne independent home: its own kitchen, bathroom and entrance.6 animals
No more than six adult animals over the age of four months are permitted per dwelling unit.
- Maximum vehicle repair duration30 days
Repair of a particular vehicle shall be conducted and completed in no more than 30 days.
- Mobile homeManufactured homeA dwelling built in a factory to a federal standard and transported to the site. minimum roof overhang16 in
Roofs shall have a minimum roof overhang of 16 inches.
- Mobile homeManufactured homeA dwelling built in a factory to a federal standard and transported to the site. nonreflective materials required
Roofing and siding materials shall be nonreflective.
- Mobile homeManufactured homeA dwelling built in a factory to a federal standard and transported to the site. permanent foundation required
Mobile homes must be located on a permanent foundation system.
- Nonconformance
All nonconforming uses, nonconforming structures, and nonconforming lots are subject to the provisions of Chapter 24.465.
- Open storage in front yardYardThe open space left between a building and its lot line — the space a setback creates.
Open storage in the front yard is not permitted in this zone.
- Temporary uses
Temporary uses may be conducted in the R-1-B zone only to the extent permitted by Chapter 24.120.
- Vehicle painting prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
Painting of a vehicle or any portion of a vehicle is prohibited.
- Vehicle repair hours
Vehicle repairs may be conducted only between the hours of 7:00 a.m. and 10:00 p.m.
- Wild animals prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
Wild animals are not permitted in the R-1-B zone.
- Wireless minor director's permit required
Uses classified in the Wireless Telecommunications Facilities: Minor use type shall require a director’s permit pursuant to Chapter 24.505.
Overlay
- Coastal overlayOverlay districtA second set of rules laid over the base district, adding requirements without replacing it. compliance
All development within the CP overlay zone must comply with the provisions of Chapters 24.310 and 24.515.
- FloodplainFloodplainLand expected to flood at a stated frequency, where building carries extra conditions. overlayOverlay districtA second set of rules laid over the base district, adding requirements without replacing it. compliance
All development within a designated floodplain (FP) overlay zone must comply with the provisions of Chapters 24.320 and 24.530.
From the ordinance
Each lot in this zone shall have a minimum area of 3,200 square feet. ... no portion of a building or other structure in the R-1-B zone shall exceed 30 feet in height.