§ 125-30.3
Dimensional standards
Extracted standards
7 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Landscaped buffer width4 ft
The standard buffer shall consist of a landscaped strip at least four feet wide outside the perimeter of the area where tower accessory structures and equipment are located at ground level.
- Temporary mobile site duration90 days
Temporary mobile communications sites and equipment may be permitted on a case-by-case analysis by the Board of Supervisors and shall be limited to 90 days.
- Minimum collocations per tower7 users
Each tower should allow for a minimum of seven collocations.
- Maximum tower heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.199 ft
No tower shall exceed 199 feet in height unless determined by the governing body that a larger tower is more preferable.
- Tower removal after cessation12 months
All unused towers and antennas must be removed within 12 months of cessation of operation or use.
- Tower separation from residences500 ft
Towers shall not be located within 500 feet of any residence other than the residence(s) on the parcel on which the tower is to be located.
- Tower setbackSetbackThe distance a building must be held back from a lot line. from property line
Tower structures shall be set back from the property line a distance equal to the height of the tower.
From the ordinance
All towers and antennas shall comply with all applicable rules and regulations of the FCC and FAA...