Sec 70-624
Extracted standards
7 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Lighting
- Maximum horizontal illumination at canopy perimeter12 foot-candles
Horizontal illumination shall not exceed twelve (12) foot-candles at the perimeter of the canopy.
- Maximum angle from grade for ground-mounted accent lighting45 degrees
central axis of the light beam from the luminaire does not exceed an angle of forty-five (45) degrees from finished grade
- Maximum luminaire mounting heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for other development25 ft
twenty-five (25) feet for all other development
- Maximum luminaire mounting heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for residential development20 ft
maximum height of a luminaire installed for residential development shall be twenty (20) feet
- Maximum spillover light at property line0.5 foot-candles
Lighting intensity shall not exceed 0.5 foot-candle at the property line(s)
- ProhibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. lighting types
Luminaries that imitate an official highway or traffic control light or sign; Luminaries that obscure or inhibit visibility of any traffic control light or sign; Luminaries that have a flashing or intermittent pattern of illumination; Privately-owned luminaries located in a public right-of-way; Searchlights and aerial lasers; Open-flame gas lamps; Mercury vapor luminaries; Luminaries equipped with adjustable mounting devices
- All luminaries shall be fully shielded and full-cutoff
All luminaries shall be fully shielded and full-cutoff
From the ordinance
Lighting intensity shall not exceed 0.5 foot-candle at the property line(s)... maximum height of a luminaire installed for residential development shall be twenty (20) feet, and twenty-five (25) feet for all other development... Horizontal illumination shall not exceed twelve (12) foot-candles at the perimeter of the canopy.